Electrodiffusion Diagnostics of Apparent Wall Slip in Polymer Solutions.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F09%3A00022433" target="_blank" >RIV/61989100:27360/09:00022433 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrodiffusion Diagnostics of Apparent Wall Slip in Polymer Solutions.
Popis výsledku v původním jazyce
Both the thermal anemometry [1] and electrodiffusion diagnostics [2], [3] were before now used to measuring near-to-wall velocity profile. These results were rather qualitative because of high uncertainties, both in used experimental technique and interpreting theory. Improvements of the mentioned electrodiffusion method consist in: (i) relating the mass-transfer coefficients to well-specified points on the velocity profile, (ii ) simultaneous using a set of circular probes of diameters ranging from 0.2to 2.0 mm, (iii) improving theory by solving full 3D equation of convective diffusion [4], (iv) careful manufacture and calibration of the circular ED probes [4], and (v) using the potentiostatic transients to independent determination [4] of the diffusivities. According to calibration experiments with Newtonian liquids, inaccuracies of the determined velocity profiles are below 10% in both variables. Using this method, some data, over a range of shear stresses, were obtained about the
Název v anglickém jazyce
Electrodiffusion Diagnostics of Apparent Wall Slip in Polymer Solutions.
Popis výsledku anglicky
Both the thermal anemometry [1] and electrodiffusion diagnostics [2], [3] were before now used to measuring near-to-wall velocity profile. These results were rather qualitative because of high uncertainties, both in used experimental technique and interpreting theory. Improvements of the mentioned electrodiffusion method consist in: (i) relating the mass-transfer coefficients to well-specified points on the velocity profile, (ii ) simultaneous using a set of circular probes of diameters ranging from 0.2to 2.0 mm, (iii) improving theory by solving full 3D equation of convective diffusion [4], (iv) careful manufacture and calibration of the circular ED probes [4], and (v) using the potentiostatic transients to independent determination [4] of the diffusivities. According to calibration experiments with Newtonian liquids, inaccuracies of the determined velocity profiles are below 10% in both variables. Using this method, some data, over a range of shear stresses, were obtained about the
Klasifikace
Druh
M - Uspořádání konference
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA104%2F09%2F0972" target="_blank" >GA104/09/0972: Přístěnné efekty při toku mikrodisperzních kapalin: zdánlivý skluz a elektrokinetický potenciál</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Místo konání akce
Cardiff, Great Britain
Stát konání akce
GB - Spojené království Velké Británie a Severního Irska
Datum zahájení akce
—
Datum ukončení akce
—
Celkový počet účastníků
320
Počet zahraničních účastníků
190
Typ akce podle státní přísl. účastníků
WRD - Celosvětová akce