Diagnostics of Apparent Wall Slip in Aqueous Polymer Solutions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F09%3A00022434" target="_blank" >RIV/61989100:27360/09:00022434 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/67985858:_____/09:00328000
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Diagnostics of Apparent Wall Slip in Aqueous Polymer Solutions
Popis výsledku v původním jazyce
Both the thermal anemometry [1] and electrodiffusion diagnostics [2], [3] were before now used to measuring near-to-wall velocity profile. These results were rather qualitative because of high uncertainties, both in used experimental technique and interpreting theory. Improvements of the mentioned electrodiffusion method consist in: (i) relating the mass-transfer coefficients to well-specified points on the velocity profile, (ii ) simultaneous using a set of circular probes of diameters ranging from 0.2to 2.0 mm, (iii) improving theory by solving full 3D equation of convective diffusion [4], (iv) careful manufacture and calibration of the circular ED probes [4], and (v) using the potentiostatic transients to independent determination [4] of the diffusivities. According to calibration experiments with Newtonian liquids, inaccuracies of the determined velocity profiles are below 10% in both variables. Using this method, some data, over a range of shear stresses, were obtained about the
Název v anglickém jazyce
Diagnostics of Apparent Wall Slip in Aqueous Polymer Solutions
Popis výsledku anglicky
Both the thermal anemometry [1] and electrodiffusion diagnostics [2], [3] were before now used to measuring near-to-wall velocity profile. These results were rather qualitative because of high uncertainties, both in used experimental technique and interpreting theory. Improvements of the mentioned electrodiffusion method consist in: (i) relating the mass-transfer coefficients to well-specified points on the velocity profile, (ii ) simultaneous using a set of circular probes of diameters ranging from 0.2to 2.0 mm, (iii) improving theory by solving full 3D equation of convective diffusion [4], (iv) careful manufacture and calibration of the circular ED probes [4], and (v) using the potentiostatic transients to independent determination [4] of the diffusivities. According to calibration experiments with Newtonian liquids, inaccuracies of the determined velocity profiles are below 10% in both variables. Using this method, some data, over a range of shear stresses, were obtained about the
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CI - Průmyslová chemie a chemické inženýrství
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Novel Trends in Rheology Proceedings of the International Conference Zlin, Czech Republic
ISBN
978-0-7354-0689-6
ISSN
—
e-ISSN
—
Počet stran výsledku
12
Strana od-do
—
Název nakladatele
Springer Heidelberg
Místo vydání
Berlín
Místo konání akce
Zlín, Česká Republika
Datum konání akce
28. 7. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—