Comparison of phase transformation temperatures for steels determined by several methods
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F11%3A86081347" target="_blank" >RIV/61989100:27360/11:86081347 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of phase transformation temperatures for steels determined by several methods
Popis výsledku v původním jazyce
The paper is focused on comparison of different methods of determination of phase transformation temperatures. We paid our attention to C-Mn and C-Mn-V-Nb steels. Different methods of temperature measurements were chosen, namely by means of the temperature scanner, dilatometer and differential thermal analysis (DTA). In case of all these methods the specimens of both steels were heated to the temperature of 1050°C, with dwell of 7 minutes at this temperature. For the C-Mn-V-Nb steel, the experiments were completed with one more measurement, where the specimen was heated to 1200°C, with dwell of 30 minutes, with the aim to ensure dissolving of the precipitates. Two temperatures, Ar3 and Ar1, were examined. The sub-range of individual temperatures in case of all used methods does not exceed 25°C.
Název v anglickém jazyce
Comparison of phase transformation temperatures for steels determined by several methods
Popis výsledku anglicky
The paper is focused on comparison of different methods of determination of phase transformation temperatures. We paid our attention to C-Mn and C-Mn-V-Nb steels. Different methods of temperature measurements were chosen, namely by means of the temperature scanner, dilatometer and differential thermal analysis (DTA). In case of all these methods the specimens of both steels were heated to the temperature of 1050°C, with dwell of 7 minutes at this temperature. For the C-Mn-V-Nb steel, the experiments were completed with one more measurement, where the specimen was heated to 1200°C, with dwell of 30 minutes, with the aim to ensure dissolving of the precipitates. Two temperatures, Ar3 and Ar1, were examined. The sub-range of individual temperatures in case of all used methods does not exceed 25°C.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Hutnické listy
ISSN
0018-8069
e-ISSN
—
Svazek periodika
64
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
4
Strana od-do
66-69
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—