HYDROGEN EMBRITTLEMENT OF DUPLEX STEEL 22/05
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F11%3A86081426" target="_blank" >RIV/61989100:27360/11:86081426 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
HYDROGEN EMBRITTLEMENT OF DUPLEX STEEL 22/05
Popis výsledku v původním jazyce
The presented paper evaluates hydrogen embrittlement of a duplex steel 22/05 with ferritic-austenitic microstructure. Tensile specimens with diameter d0 = 4 mm were electrolytically hydrogen charged in 0.1 N solution of H2SO4, without or with addition of1 g of KSCN per 1 liter of solution, for 24 hours or 168 hours. The current density for hydrogen charging varied from i = 1 to 5 mA.cm-2. Tensile tests with low strain rate were performed immediately after hydrogen charging. Impact of hydrogen on mechanical properties of the duplex steel during tensile test was confirmed by decreasing of plastic properties, especially reduction in area. Degree of embrittlement was expressed by the index of hydrogen embrittlement F. Hydrogen charging at current densityi = 1 mA.cm-2 caused almost none embrittlement of the steel studied, index of hydrogen embrittlement F = 0.8 %. Some decreasing of reduction in area was observed for increased current density 5 mA.cm-2, but the index of hydrogen embrittle
Název v anglickém jazyce
HYDROGEN EMBRITTLEMENT OF DUPLEX STEEL 22/05
Popis výsledku anglicky
The presented paper evaluates hydrogen embrittlement of a duplex steel 22/05 with ferritic-austenitic microstructure. Tensile specimens with diameter d0 = 4 mm were electrolytically hydrogen charged in 0.1 N solution of H2SO4, without or with addition of1 g of KSCN per 1 liter of solution, for 24 hours or 168 hours. The current density for hydrogen charging varied from i = 1 to 5 mA.cm-2. Tensile tests with low strain rate were performed immediately after hydrogen charging. Impact of hydrogen on mechanical properties of the duplex steel during tensile test was confirmed by decreasing of plastic properties, especially reduction in area. Degree of embrittlement was expressed by the index of hydrogen embrittlement F. Hydrogen charging at current densityi = 1 mA.cm-2 caused almost none embrittlement of the steel studied, index of hydrogen embrittlement F = 0.8 %. Some decreasing of reduction in area was observed for increased current density 5 mA.cm-2, but the index of hydrogen embrittle
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
20th Anniversary International Conference on Metallurgy and Materials: METAL 2011
ISBN
978-80-87294-24-6
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
571-576