INFLUENCE OF THERMO HYDROGEN TREATMENT ON HOT DEFORMATION BEHAVIOR AND MICROSTRUCTURAL EVOLUTION OF TI-6AL-4V ALLOY
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F14%3A86090200" target="_blank" >RIV/61989100:27360/14:86090200 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.comat.cz/files/proceedings/19/reports/3401.pdf" target="_blank" >http://www.comat.cz/files/proceedings/19/reports/3401.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
INFLUENCE OF THERMO HYDROGEN TREATMENT ON HOT DEFORMATION BEHAVIOR AND MICROSTRUCTURAL EVOLUTION OF TI-6AL-4V ALLOY
Popis výsledku v původním jazyce
The influence of hydrogen on hot deformation behavior and the microstructure evolution of Ti-6Al-4V was investigated. Specimens in hydrogenated and non-hydrogenated state were tested by means of isothermal compression at 800 °C and strain rate of 0.005 s-1 on a Gleeble-3800 machine. Thermal hydrogen treatment of specimens in flowing hydrogen consisted of annealing 1 h at 600 °C, 0.5 h at 850 °C and aging 4 h at 590 °C. Hydrogen contents in specimens at conditions as-received, heat treated in argon and in hydrogen and after isothermal compression test were measured using an analyzer LECO RH600. Thermal hydrogen treatment resulted in amount of hydrogen as high as 0.98 wt. %. After isothermal compression test the hydrogen content of 0.46 wt. % was retained in the specimens. Metallographic study of microstructure evolution after isothermal compression revealed martensite needles and rare and very fine alpha phase grains confirming that the specimens were deformed above the beta transus tem
Název v anglickém jazyce
INFLUENCE OF THERMO HYDROGEN TREATMENT ON HOT DEFORMATION BEHAVIOR AND MICROSTRUCTURAL EVOLUTION OF TI-6AL-4V ALLOY
Popis výsledku anglicky
The influence of hydrogen on hot deformation behavior and the microstructure evolution of Ti-6Al-4V was investigated. Specimens in hydrogenated and non-hydrogenated state were tested by means of isothermal compression at 800 °C and strain rate of 0.005 s-1 on a Gleeble-3800 machine. Thermal hydrogen treatment of specimens in flowing hydrogen consisted of annealing 1 h at 600 °C, 0.5 h at 850 °C and aging 4 h at 590 °C. Hydrogen contents in specimens at conditions as-received, heat treated in argon and in hydrogen and after isothermal compression test were measured using an analyzer LECO RH600. Thermal hydrogen treatment resulted in amount of hydrogen as high as 0.98 wt. %. After isothermal compression test the hydrogen content of 0.46 wt. % was retained in the specimens. Metallographic study of microstructure evolution after isothermal compression revealed martensite needles and rare and very fine alpha phase grains confirming that the specimens were deformed above the beta transus tem
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JJ - Ostatní materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
COMAT 2014 : recent trends in structural materials : conference proceedings : November 19th - 21th 2014, Parkhotel Plzen, Pilsen, Czech Republic, EU
ISBN
978-80-87294-45-1
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
3401
Název nakladatele
Tanger
Místo vydání
Ostrava
Místo konání akce
Plzeň
Datum konání akce
19. 11. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—