Hydrogen response of 304 SS and Ti weld realised by explosion
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F14%3A86091213" target="_blank" >RIV/61989100:27360/14:86091213 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/MSF.782.166" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/MSF.782.166</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/MSF.782.166" target="_blank" >10.4028/www.scientific.net/MSF.782.166</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Hydrogen response of 304 SS and Ti weld realised by explosion
Popis výsledku v původním jazyce
Welds of thick plates (304 SS) cladded with Ti of commercial purity both in as received state and subsequently heat treated (HT, 600 °C/1.5 h/air), charged by hydrogen, were investigated after fatigue tests (tension-pressure) with amplitude of 20 Hz. Simultaneously, samples of above mentioned welds were also exposed in H2S in accord with NACE Standard TM0284-2011 to find hydrogen induced cracking (HIC) response. Charged welds after the HT showed by 15 MPa higher threshold level than the welds without the HT. The HIC tests generally demonstrated favourable results both after as weld state and after subsequent HT. Short and thin cracks were observed, exclusively located in intermetallic phase areas, where approx. 16-20 wt. % of Ti was revealed. Fracturesurfaces of fatigue bars showed maximal failure in areas with 42-97 wt. % of Ti.
Název v anglickém jazyce
Hydrogen response of 304 SS and Ti weld realised by explosion
Popis výsledku anglicky
Welds of thick plates (304 SS) cladded with Ti of commercial purity both in as received state and subsequently heat treated (HT, 600 °C/1.5 h/air), charged by hydrogen, were investigated after fatigue tests (tension-pressure) with amplitude of 20 Hz. Simultaneously, samples of above mentioned welds were also exposed in H2S in accord with NACE Standard TM0284-2011 to find hydrogen induced cracking (HIC) response. Charged welds after the HT showed by 15 MPa higher threshold level than the welds without the HT. The HIC tests generally demonstrated favourable results both after as weld state and after subsequent HT. Short and thin cracks were observed, exclusively located in intermetallic phase areas, where approx. 16-20 wt. % of Ti was revealed. Fracturesurfaces of fatigue bars showed maximal failure in areas with 42-97 wt. % of Ti.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED0040%2F01%2F01" target="_blank" >ED0040/01/01: Regionální materiálově technologické výzkumné centrum</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Materials Science Forum
ISSN
0255-5476
e-ISSN
—
Svazek periodika
782
Číslo periodika v rámci svazku
April 2014
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
6
Strana od-do
166-171
Kód UT WoS článku
000338978600028