DETERMINATION OF THE OVERALL VALUE OF THE HEAT TRANSFER COEFFICIENT ON THE OUTSIDE OF THE CYLINDRICAL WALL
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27360%2F23%3A10252955" target="_blank" >RIV/61989100:27360/23:10252955 - isvavai.cz</a>
Výsledek na webu
<a href="https://dspace.vsb.cz/handle/10084/151453" target="_blank" >https://dspace.vsb.cz/handle/10084/151453</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
DETERMINATION OF THE OVERALL VALUE OF THE HEAT TRANSFER COEFFICIENT ON THE OUTSIDE OF THE CYLINDRICAL WALL
Popis výsledku v původním jazyce
The subject of the present paper is to determine the total value of the heat transfer coefficient on the outside of an uninsulated heat pipe passing through a room by means of mathematical and physical analysis. The calculation is performed for two variants of the piping. The calculations performed can be used in the next stage to determine the total heat loss or the amount of heat transferred to the surroundings from the pipe casing surface and subsequently to design the optimum pipe insulation thickness. Based on the design of the optimal pipe insulation thickness, it is also possible to further evaluate the investment and operating costs of both new and existing hot water piping systems.
Název v anglickém jazyce
DETERMINATION OF THE OVERALL VALUE OF THE HEAT TRANSFER COEFFICIENT ON THE OUTSIDE OF THE CYLINDRICAL WALL
Popis výsledku anglicky
The subject of the present paper is to determine the total value of the heat transfer coefficient on the outside of an uninsulated heat pipe passing through a room by means of mathematical and physical analysis. The calculation is performed for two variants of the piping. The calculations performed can be used in the next stage to determine the total heat loss or the amount of heat transferred to the surroundings from the pipe casing surface and subsequently to design the optimum pipe insulation thickness. Based on the design of the optimal pipe insulation thickness, it is also possible to further evaluate the investment and operating costs of both new and existing hot water piping systems.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20500 - Materials engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PhD students´ day FMST 2023
ISBN
978-80-248-4697-2
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
84-87
Název nakladatele
Vysoká škola báňská - Technická univerzita Ostrava
Místo vydání
Ostrava
Místo konání akce
Ostrava
Datum konání akce
15. 6. 2023
Typ akce podle státní příslušnosti
CST - Celostátní akce