FENTON'S REACTION AS A METHOD FOR WASTEWATER TREATMENT AFTER GASIFICA-TION OF BIOMASS. THE MAIN PARAMETERS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27650%2F15%3A86090296" target="_blank" >RIV/61989100:27650/15:86090296 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
FENTON'S REACTION AS A METHOD FOR WASTEWATER TREATMENT AFTER GASIFICA-TION OF BIOMASS. THE MAIN PARAMETERS
Popis výsledku v původním jazyce
One of the methods for obtaining alternative sources of energy is biomass gasification. During this process wastewater with a high organic load is generated. The wastewater contains toxic, mutagenic, carcinogenic and refraction substances. It therefore seems reasonable to use chemical pretreatment before discharge into the sewer system. The literature data reported the raw sewage causes the collapse of biological systems for wastewater treatment plants. Due to the nature of the wastewater, a method fromthe group belonging to advanced oxidation processes (AOP's), which include Fenton's reaction, will be indicated. In the article it is shown how important the selection of the Fenton reaction parameters is. Parameters should always be chosen experimentally, de-pending on the effects that we want to obtain. The removal rate is affected by both hydrogen peroxide and iron ions, however, the amount of pollution re-moved is affected by hydrogen peroxide. Correction of the initial and final pH
Název v anglickém jazyce
FENTON'S REACTION AS A METHOD FOR WASTEWATER TREATMENT AFTER GASIFICA-TION OF BIOMASS. THE MAIN PARAMETERS
Popis výsledku anglicky
One of the methods for obtaining alternative sources of energy is biomass gasification. During this process wastewater with a high organic load is generated. The wastewater contains toxic, mutagenic, carcinogenic and refraction substances. It therefore seems reasonable to use chemical pretreatment before discharge into the sewer system. The literature data reported the raw sewage causes the collapse of biological systems for wastewater treatment plants. Due to the nature of the wastewater, a method fromthe group belonging to advanced oxidation processes (AOP's), which include Fenton's reaction, will be indicated. In the article it is shown how important the selection of the Fenton reaction parameters is. Parameters should always be chosen experimentally, de-pending on the effects that we want to obtain. The removal rate is affected by both hydrogen peroxide and iron ions, however, the amount of pollution re-moved is affected by hydrogen peroxide. Correction of the initial and final pH
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
DJ - Znečištění a kontrola vody
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Converted fuel and not only that : selected issues
ISBN
978-80-248-3685-0
Počet stran výsledku
15
Strana od-do
114-128
Počet stran knihy
150
Název nakladatele
VŠB - Technická univerzita Ostrava
Místo vydání
Ostrava
Kód UT WoS kapitoly
—