A Robust Grid-Voltage-Modulated Direct Power Control Strategy for Three-Phase Four-Leg Rectifiers Under Uncertainties and Disturbances Using Super-Twisting and Nonlinear Varying-Gain Observer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27730%2F25%3A10259263" target="_blank" >RIV/61989100:27730/25:10259263 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/11196070" target="_blank" >https://ieeexplore.ieee.org/document/11196070</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ACCESS.2025.3619428" target="_blank" >10.1109/ACCESS.2025.3619428</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Robust Grid-Voltage-Modulated Direct Power Control Strategy for Three-Phase Four-Leg Rectifiers Under Uncertainties and Disturbances Using Super-Twisting and Nonlinear Varying-Gain Observer
Popis výsledku v původním jazyce
This paper presents an enhanced control strategy for a three-phase four-wire four-leg rectifier (3P4W4LR), aimed at improving dynamic and steady-state performances, disturbance rejection, robustness, and implementation efficiency. A nonlinear varying-gain observer (NVGO) integrated with a simple PI controller is proposed for the outer loop to regulate the DC-link voltage under different internal and external disturbances. Unlike traditional disturbance observers, which are highly sensitive to measurement noise and compromise transient response when gains are reduced, the proposed NVGO employs a variable-gain mechanism. High gain value is used during transients to ensure rapid disturbance estimation and rejection, while low gain value during steady-state minimizes noise sensitivity and estimation error. This results in superior disturbance rejection, improved dynamic response, reduced DC-link voltage steady-state error, enhanced noise immunity, increased reliability, and reduced system size and cost. For the inner loop, a grid-voltage-modulated direct power control method based on super-twisting sliding mode control is introduced. Operating directly in the synchronous reference frame without relying on phase-locked loop or Park transformations, this approach simplifies implementation while delivering faster transient response, improved steady-state accuracy, and greater resilience to grid current system uncertainties and disturbances. To ensure robust performance, the closed-loop regional stability of the proposed NVGO with PI controller is rigorously analyzed using a piecewise quadratic Lyapunov function. The effectiveness and superiority of the proposed method are validated through both simulations and real-time hardware-in-the-loop testing. Extensive testing under dynamic load conditions, different grid voltage conditions, and DC-link capacitance uncertainty demonstrates the controller's robust performance and practical viability.
Název v anglickém jazyce
A Robust Grid-Voltage-Modulated Direct Power Control Strategy for Three-Phase Four-Leg Rectifiers Under Uncertainties and Disturbances Using Super-Twisting and Nonlinear Varying-Gain Observer
Popis výsledku anglicky
This paper presents an enhanced control strategy for a three-phase four-wire four-leg rectifier (3P4W4LR), aimed at improving dynamic and steady-state performances, disturbance rejection, robustness, and implementation efficiency. A nonlinear varying-gain observer (NVGO) integrated with a simple PI controller is proposed for the outer loop to regulate the DC-link voltage under different internal and external disturbances. Unlike traditional disturbance observers, which are highly sensitive to measurement noise and compromise transient response when gains are reduced, the proposed NVGO employs a variable-gain mechanism. High gain value is used during transients to ensure rapid disturbance estimation and rejection, while low gain value during steady-state minimizes noise sensitivity and estimation error. This results in superior disturbance rejection, improved dynamic response, reduced DC-link voltage steady-state error, enhanced noise immunity, increased reliability, and reduced system size and cost. For the inner loop, a grid-voltage-modulated direct power control method based on super-twisting sliding mode control is introduced. Operating directly in the synchronous reference frame without relying on phase-locked loop or Park transformations, this approach simplifies implementation while delivering faster transient response, improved steady-state accuracy, and greater resilience to grid current system uncertainties and disturbances. To ensure robust performance, the closed-loop regional stability of the proposed NVGO with PI controller is rigorously analyzed using a piecewise quadratic Lyapunov function. The effectiveness and superiority of the proposed method are validated through both simulations and real-time hardware-in-the-loop testing. Extensive testing under dynamic load conditions, different grid voltage conditions, and DC-link capacitance uncertainty demonstrates the controller's robust performance and practical viability.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20200 - Electrical engineering, Electronic engineering, Information engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/TN02000025" target="_blank" >TN02000025: Národní centrum pro energetiku II</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
IEEE Access
ISSN
2169-3536
e-ISSN
—
Svazek periodika
13
Číslo periodika v rámci svazku
Volume: 13
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
28
Strana od-do
175624-175651
Kód UT WoS článku
001594893600016