Remodelace kosti, částicová nemoc a individuální vnímavost k periprotetické osteolýze
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F08%3A00006107" target="_blank" >RIV/61989592:15110/08:00006107 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Bone remodelling, particle disease and individual susceptibility to periprosthetic osteolysis.
Popis výsledku v původním jazyce
Bone remodelling is a tightly coupled process consisting of repetitive cycles of bone resorption and formation. Both processes are governed by mechanical signals, which operate in conjunction with local, and systemic factors in a discrete anatomic structure designated a basic multicellular unit (BMU). The microenvironment around total joint arthroplasty is a dynamic and complex milieu influenced by the chemical and physical stimuli associated with servicing the prosthesis. A key factor limiting the longevity of the prosthesis is polyethylene wear, which induces particle disease, and this may lead to increased and prolonged activity of BMUs resulting in periprosthetic osteolysis. Several pathways regulating BMU function have been reported in the past, including RANKL/RANK/OPG/TRAF6, TNF-?/TNFR/TRAF1, and IL-6/CD126/JAK/STAT. Moreover, the expression and functional activity of all these molecules can be affected by variations in their genes. These may explain the differences in severity
Název v anglickém jazyce
Bone remodelling, particle disease and individual susceptibility to periprosthetic osteolysis.
Popis výsledku anglicky
Bone remodelling is a tightly coupled process consisting of repetitive cycles of bone resorption and formation. Both processes are governed by mechanical signals, which operate in conjunction with local, and systemic factors in a discrete anatomic structure designated a basic multicellular unit (BMU). The microenvironment around total joint arthroplasty is a dynamic and complex milieu influenced by the chemical and physical stimuli associated with servicing the prosthesis. A key factor limiting the longevity of the prosthesis is polyethylene wear, which induces particle disease, and this may lead to increased and prolonged activity of BMUs resulting in periprosthetic osteolysis. Several pathways regulating BMU function have been reported in the past, including RANKL/RANK/OPG/TRAF6, TNF-?/TNFR/TRAF1, and IL-6/CD126/JAK/STAT. Moreover, the expression and functional activity of all these molecules can be affected by variations in their genes. These may explain the differences in severity
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FN - Epidemiologie, infekční nemoci a klinická imunologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NR9490" target="_blank" >NR9490: Predikce rizika vzniku závažné osteolýzy u TEP kyčelního kloubu na základě vyšetření vybraných cytokinových polymorfismů typu SNP</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Physiological Research (print)
ISSN
0862-8408
e-ISSN
—
Svazek periodika
57
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
11
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—