The effect of a cardiopulmonary bypass system with biocompatible coating on fibrinogen levels determined by the TEG--functional fibrinogen method: preliminary results
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F11%3A33119515" target="_blank" >RIV/61989592:15110/11:33119515 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00098892:_____/11:#0000129
Výsledek na webu
<a href="http://dx.doi.org/10.1177/0267659111415891" target="_blank" >http://dx.doi.org/10.1177/0267659111415891</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1177/0267659111415891" target="_blank" >10.1177/0267659111415891</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The effect of a cardiopulmonary bypass system with biocompatible coating on fibrinogen levels determined by the TEG--functional fibrinogen method: preliminary results
Popis výsledku v původním jazyce
When cardiopulmonary bypass (CPB) is used, the blood comes into contact with foreign surfaces. To diminish this impact, various types of biocompatibly coated surfaces have been developed. The study assessed the effects of heparin-coated CPB systems on the level and function of fibrinogen as measured by thromboelastography (TEG), as compared with non-coated systems. No statistically significant differences between both groups were revealed by comparing paired data. In our study, heparin-coated CPB circuits had no significant effect on either fibrinogen level or its function
Název v anglickém jazyce
The effect of a cardiopulmonary bypass system with biocompatible coating on fibrinogen levels determined by the TEG--functional fibrinogen method: preliminary results
Popis výsledku anglicky
When cardiopulmonary bypass (CPB) is used, the blood comes into contact with foreign surfaces. To diminish this impact, various types of biocompatibly coated surfaces have been developed. The study assessed the effects of heparin-coated CPB systems on the level and function of fibrinogen as measured by thromboelastography (TEG), as compared with non-coated systems. No statistically significant differences between both groups were revealed by comparing paired data. In our study, heparin-coated CPB circuits had no significant effect on either fibrinogen level or its function
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NS9614" target="_blank" >NS9614: Stanovení vlivu biokompatibiní úpravy vnitřního povrchu systému pro mimotělní oběh na funkci fibrinogenu metodou TEG Funkční Fibrinogen</a><br>
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Perfusion
ISSN
0267-6591
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
503-509
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—