Comparison of functional fibrinogen assessment using thromboelastography with the standard von Clauss method.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F12%3A33140097" target="_blank" >RIV/61989592:15110/12:33140097 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00098892:_____/12:#0000227
Výsledek na webu
<a href="http://dx.doi.org/10.5507/bp.2011.035" target="_blank" >http://dx.doi.org/10.5507/bp.2011.035</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5507/bp.2011.035" target="_blank" >10.5507/bp.2011.035</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of functional fibrinogen assessment using thromboelastography with the standard von Clauss method.
Popis výsledku v původním jazyce
To compare assessment of fibrinogen by thromboelastography with the standard von Clauss method. METHODS: Observational prospective study. RESULTS: Thromboelastography provides direct and complex evaluation of the entire coagulation cascade based upon changes in blood viscosity. It affects both platelets and plasma components. AIM:New application of this method measures fibrinogen contribution to coagulation as opposed to fibrinogen antigen levels measured by immunoassay. Paired samples from 117 patientsbefore cardiopulmonary bypass were compared. A moderate correlation was found between fibrinogen and functional fibrinogen with a Spearman correlation coefficient of 0.476. CONCLUSION: The functional fibrinogen test is a valid point-of-care method for fibrinogen assay with a moderate correlation to the standard method.
Název v anglickém jazyce
Comparison of functional fibrinogen assessment using thromboelastography with the standard von Clauss method.
Popis výsledku anglicky
To compare assessment of fibrinogen by thromboelastography with the standard von Clauss method. METHODS: Observational prospective study. RESULTS: Thromboelastography provides direct and complex evaluation of the entire coagulation cascade based upon changes in blood viscosity. It affects both platelets and plasma components. AIM:New application of this method measures fibrinogen contribution to coagulation as opposed to fibrinogen antigen levels measured by immunoassay. Paired samples from 117 patientsbefore cardiopulmonary bypass were compared. A moderate correlation was found between fibrinogen and functional fibrinogen with a Spearman correlation coefficient of 0.476. CONCLUSION: The functional fibrinogen test is a valid point-of-care method for fibrinogen assay with a moderate correlation to the standard method.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FA - Kardiovaskulární nemoci včetně kardiochirurgie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NS9614" target="_blank" >NS9614: Stanovení vlivu biokompatibiní úpravy vnitřního povrchu systému pro mimotělní oběh na funkci fibrinogenu metodou TEG Funkční Fibrinogen</a><br>
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Papers-Olomouc
ISSN
1213-8118
e-ISSN
—
Svazek periodika
156
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
2
Strana od-do
260-261
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—