Glucose concentrations in blood and tissue - a pilot study on variable time lag
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F15%3A33155127" target="_blank" >RIV/61989592:15110/15:33155127 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Glucose concentrations in blood and tissue - a pilot study on variable time lag
Popis výsledku v původním jazyce
The aim of this pilot study was to acquire insight into the parameters of glycaemic control, especially, (1) the time delay (lag phase) between plasma and tissue glucose concentrations in relation to rise and fall in glucose levels and (2) the rate of glucose increase and decrease. Four healthy people (HP), 4 people with type 1 diabetes (DM1) and 4 with type 2 diabetes (DM2) underwent concurrent glucose measurements by means of (1) the continuous glucose monitoring (CGMS-Medtronic), Medtronic-Minimed, CA, USA, calibrated by the glucometers Calla, Wellion, Austria, and, (2) the Beckman II analyser to measure glucose concentrations in venous plasma. Samples were taken on 4 consecutive days in the fasting state and 4 times after consumption of 50 g glucose. Carelink Personal, MS Excel, Maple and Mat lab were applied to plot the evolution of glucose concentration and analyse the results. The time difference between increase and decrease was calculated for HP, DM 1 and DM 2.
Název v anglickém jazyce
Glucose concentrations in blood and tissue - a pilot study on variable time lag
Popis výsledku anglicky
The aim of this pilot study was to acquire insight into the parameters of glycaemic control, especially, (1) the time delay (lag phase) between plasma and tissue glucose concentrations in relation to rise and fall in glucose levels and (2) the rate of glucose increase and decrease. Four healthy people (HP), 4 people with type 1 diabetes (DM1) and 4 with type 2 diabetes (DM2) underwent concurrent glucose measurements by means of (1) the continuous glucose monitoring (CGMS-Medtronic), Medtronic-Minimed, CA, USA, calibrated by the glucometers Calla, Wellion, Austria, and, (2) the Beckman II analyser to measure glucose concentrations in venous plasma. Samples were taken on 4 consecutive days in the fasting state and 4 times after consumption of 50 g glucose. Carelink Personal, MS Excel, Maple and Mat lab were applied to plot the evolution of glucose concentration and analyse the results. The time difference between increase and decrease was calculated for HP, DM 1 and DM 2.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FB - Endokrinologie, diabetologie, metabolismus, výživa
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Papers-Olomouc
ISSN
1213-8118
e-ISSN
—
Svazek periodika
159
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
8
Strana od-do
527-534
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—