Prolonged treatment planning can increase real rectal dose in 3D brachytherapy for cervical cancer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F20%3A73602243" target="_blank" >RIV/61989592:15110/20:73602243 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11110/20:10411691
Výsledek na webu
<a href="https://www.termedia.pl/Prolonged-treatment-planning-can-increase-real-rectal-dose-in-3D-brachytherapy-for-cervical-cancer,54,40409,1,1.html" target="_blank" >https://www.termedia.pl/Prolonged-treatment-planning-can-increase-real-rectal-dose-in-3D-brachytherapy-for-cervical-cancer,54,40409,1,1.html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5114/jcb.2020.94580" target="_blank" >10.5114/jcb.2020.94580</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Prolonged treatment planning can increase real rectal dose in 3D brachytherapy for cervical cancer
Popis výsledku v původním jazyce
Purpose: The purpose of this study was to evaluate the influence of 3D brachytherapy planning time on the real dose distribution. Material and methods: 10 patients with cervical cancer were evaluated using 2 computed tomography (CT) scans brachytherapy. The first scan was performed after the insertion of UVAG applicators, and the second was done after creating the treatment plan, just before the irradiation of first and third fraction. Both plans were compared in terms of changes of volumes and differences in the dose for high-risk organs using GEC-ESTRO Working Group parameters.
Název v anglickém jazyce
Prolonged treatment planning can increase real rectal dose in 3D brachytherapy for cervical cancer
Popis výsledku anglicky
Purpose: The purpose of this study was to evaluate the influence of 3D brachytherapy planning time on the real dose distribution. Material and methods: 10 patients with cervical cancer were evaluated using 2 computed tomography (CT) scans brachytherapy. The first scan was performed after the insertion of UVAG applicators, and the second was done after creating the treatment plan, just before the irradiation of first and third fraction. Both plans were compared in terms of changes of volumes and differences in the dose for high-risk organs using GEC-ESTRO Working Group parameters.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30204 - Oncology
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Contemporary Brachytherapy
ISSN
1689-832X
e-ISSN
—
Svazek periodika
12
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
6
Strana od-do
118-123
Kód UT WoS článku
000531069800005
EID výsledku v databázi Scopus
2-s2.0-85088988829