The Modern Pneumatic Tube System Transports with Reduced Speed Does Not Affect Special Coagulation Tests
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F20%3A73603562" target="_blank" >RIV/61989592:15110/20:73603562 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00098892:_____/20:N0000185
Výsledek na webu
<a href="https://link.springer.com/article/10.1007/s10916-020-01614-6" target="_blank" >https://link.springer.com/article/10.1007/s10916-020-01614-6</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10916-020-01614-6" target="_blank" >10.1007/s10916-020-01614-6</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Modern Pneumatic Tube System Transports with Reduced Speed Does Not Affect Special Coagulation Tests
Popis výsledku v původním jazyce
Pneumatic tube transport systems (PTS) for delivery of patient samples to a hemostasis laboratory are often used to reduce turnaround time for vital analyses. PTS in our hospital has the ability to regulate the transport speed in the range of 3–6 m/s with acceleration control technology. We evaluated the effects of PTS transport for routine coagulation tests, platelet function tests and special global coagulation tests. Duplicate samples were collected from 29 patients and 40 healthy individuals. One sample was sent using PTS and the other was carried by personnel to the lab for determination of protrombin time, activated partial thromboplastin time, trombin time, fibrinogen, antitrombin and thrombin generation test. Platelet function was measured by means of a Apact 4004® analyzer using the inductors (ADP, Arachidonic acid and Epinephrine). Samples transported using PTS with normal transport speed 6 m/s does not affect basic coagulation tests (PT, aPTT, FIB, TT and AT), but TGT has significantly altered. The use of PTS with controlled acceleration regulated the increase in thrombin generation from 10% to 3%, which is not statistically signifiant. The use of PTS with controlled acceleration did not show a significant difference even with the highly sensitive method of platelet aggregation. We conclude that PTS with acceleration control with transport speed from 3 to 6 m/s does not affect to platelet activity as measured by LTA and also global coagulation test - TGT. The advantage of PTS transport is very rapid assessment laboratory testing. From the above validation study, it is clear that PTS should always be validated for specialized laboratory methods and appropriately adapted to specific transport conditions. © 2020, Springer Science+Business Media, LLC, part of Springer Nature.
Název v anglickém jazyce
The Modern Pneumatic Tube System Transports with Reduced Speed Does Not Affect Special Coagulation Tests
Popis výsledku anglicky
Pneumatic tube transport systems (PTS) for delivery of patient samples to a hemostasis laboratory are often used to reduce turnaround time for vital analyses. PTS in our hospital has the ability to regulate the transport speed in the range of 3–6 m/s with acceleration control technology. We evaluated the effects of PTS transport for routine coagulation tests, platelet function tests and special global coagulation tests. Duplicate samples were collected from 29 patients and 40 healthy individuals. One sample was sent using PTS and the other was carried by personnel to the lab for determination of protrombin time, activated partial thromboplastin time, trombin time, fibrinogen, antitrombin and thrombin generation test. Platelet function was measured by means of a Apact 4004® analyzer using the inductors (ADP, Arachidonic acid and Epinephrine). Samples transported using PTS with normal transport speed 6 m/s does not affect basic coagulation tests (PT, aPTT, FIB, TT and AT), but TGT has significantly altered. The use of PTS with controlled acceleration regulated the increase in thrombin generation from 10% to 3%, which is not statistically signifiant. The use of PTS with controlled acceleration did not show a significant difference even with the highly sensitive method of platelet aggregation. We conclude that PTS with acceleration control with transport speed from 3 to 6 m/s does not affect to platelet activity as measured by LTA and also global coagulation test - TGT. The advantage of PTS transport is very rapid assessment laboratory testing. From the above validation study, it is clear that PTS should always be validated for specialized laboratory methods and appropriately adapted to specific transport conditions. © 2020, Springer Science+Business Media, LLC, part of Springer Nature.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30205 - Hematology
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF MEDICAL SYSTEMS
ISSN
0148-5598
e-ISSN
—
Svazek periodika
44
Číslo periodika v rámci svazku
9
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
"'142(1)'"-"'142(5)'"
Kód UT WoS článku
000550734000001
EID výsledku v databázi Scopus
2-s2.0-85088314634