Determination of one year stability of lipid plasma profile and comparison of blood collection tubes using UHPSFC/MS and HILIC-UHPLC/MS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F20%3A73603912" target="_blank" >RIV/61989592:15110/20:73603912 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216275:25310/20:39916266
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0003267020309089" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0003267020309089</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.aca.2020.08.061" target="_blank" >10.1016/j.aca.2020.08.061</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of one year stability of lipid plasma profile and comparison of blood collection tubes using UHPSFC/MS and HILIC-UHPLC/MS
Popis výsledku v původním jazyce
Effects of blood collection tubes, the time period, the sample origin, and the method used on the lipidomic profile are investigated by ultrahigh-performance supercritical fluid chromatography mass spectrometry (UHPSFC/MS) and hydrophilic interaction liquid chromatography ultrahigh-performance liquid chromatography mass spectrometry (HILIC-UHPLC/MS). Heparin plasma samples have been obtained from 99 healthy volunteers at three time points separated by six-month intervals together with one collection for EDTA plasma and serum. Furthermore, lipid concentrations in heparin plasma collected at two different sites are compared. 171 lipid species from eight lipid classes are quantified with UHPSFC/ MS, and 122 lipid species from four lipid classes with HILIC-UHPLC/MS. The accuracy of both methods is monitored by the quantitation error using two internal standards (IS) per individual lipid classes. No significant differences in lipid profiles are observed for different time points and types of collection tubes (heparin plasma, EDTA plasma, and serum). Most pronounced lipid concentration differences are observed for the comparison of NIST SRM 1950 human plasma and mean lipid concentrations of the investigated cohort. Furthermore, differences in lipid concentrations are observed between employed methods (UHPSFC/MS vs. HILIC-UHPLC/MS), which can be compensated by the normalization using NIST SRM 1950 human plasma used as the quality control sample. (c) 2020 Elsevier B.V. All rights reserved.
Název v anglickém jazyce
Determination of one year stability of lipid plasma profile and comparison of blood collection tubes using UHPSFC/MS and HILIC-UHPLC/MS
Popis výsledku anglicky
Effects of blood collection tubes, the time period, the sample origin, and the method used on the lipidomic profile are investigated by ultrahigh-performance supercritical fluid chromatography mass spectrometry (UHPSFC/MS) and hydrophilic interaction liquid chromatography ultrahigh-performance liquid chromatography mass spectrometry (HILIC-UHPLC/MS). Heparin plasma samples have been obtained from 99 healthy volunteers at three time points separated by six-month intervals together with one collection for EDTA plasma and serum. Furthermore, lipid concentrations in heparin plasma collected at two different sites are compared. 171 lipid species from eight lipid classes are quantified with UHPSFC/ MS, and 122 lipid species from four lipid classes with HILIC-UHPLC/MS. The accuracy of both methods is monitored by the quantitation error using two internal standards (IS) per individual lipid classes. No significant differences in lipid profiles are observed for different time points and types of collection tubes (heparin plasma, EDTA plasma, and serum). Most pronounced lipid concentration differences are observed for the comparison of NIST SRM 1950 human plasma and mean lipid concentrations of the investigated cohort. Furthermore, differences in lipid concentrations are observed between employed methods (UHPSFC/MS vs. HILIC-UHPLC/MS), which can be compensated by the normalization using NIST SRM 1950 human plasma used as the quality control sample. (c) 2020 Elsevier B.V. All rights reserved.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30204 - Oncology
Návaznosti výsledku
Projekt
<a href="/cs/project/GJ20-23290Y" target="_blank" >GJ20-23290Y: Absolutní kvantifikace iontových a polárních biomolekul s využitím superkritické fluidní chromatografie ve spojení s hmotnostní spektrometrií</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ANALYTICA CHIMICA ACTA
ISSN
0003-2670
e-ISSN
—
Svazek periodika
1137
Číslo periodika v rámci svazku
November 2020
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
11
Strana od-do
74-84
Kód UT WoS článku
000595332500009
EID výsledku v databázi Scopus
2-s2.0-85090714631