Stanovení methylbenzokvátu v premixech a zvířecím krmivu pomocí kapalinové chromatografie s fluorescenční detekcí
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F05%3A00002105" target="_blank" >RIV/61989592:15310/05:00002105 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of methylbenzoquate in premixes and animal feeds USING liquid chromatography with fluorescence detection
Popis výsledku v původním jazyce
A rapid analytical procedure was developed and tested for routine identification and quantification of methylbenzoquate in feeds by liquid chromatography (LC). The ground feed samples were extracted using methanol-water (80 + 20, v/v) at 65 degrees-70 degrees C in a water bath for premixes and in dichloromethane at 45 degrees C in a water bath for final feeds, respectively. The extract of final feeds was cleaned using solid-phase extraction on silica columns. Both the final feed and premix extracts wereanalyzed by reversed-phase LC on a NovaPak C18 column (3.9 x 150 mm; 4 mu m) with methanol-acetonitrile-water-phosphoric acid (340 + 350 + 308 + 2, v/v) as mobile phase. Fluorescence detection was performed at excitation and emission wavelengths of 265and 390 nm, respectively. Alternatively, post-column addition of sulfuric acid solution was used to decrease the determination limit. The recovery of methylbenzoquate, in a concentration range of 0.5-10 mg/kg, was 105.0 +/- 7.3%. The limi
Název v anglickém jazyce
Determination of methylbenzoquate in premixes and animal feeds USING liquid chromatography with fluorescence detection
Popis výsledku anglicky
A rapid analytical procedure was developed and tested for routine identification and quantification of methylbenzoquate in feeds by liquid chromatography (LC). The ground feed samples were extracted using methanol-water (80 + 20, v/v) at 65 degrees-70 degrees C in a water bath for premixes and in dichloromethane at 45 degrees C in a water bath for final feeds, respectively. The extract of final feeds was cleaned using solid-phase extraction on silica columns. Both the final feed and premix extracts wereanalyzed by reversed-phase LC on a NovaPak C18 column (3.9 x 150 mm; 4 mu m) with methanol-acetonitrile-water-phosphoric acid (340 + 350 + 308 + 2, v/v) as mobile phase. Fluorescence detection was performed at excitation and emission wavelengths of 265and 390 nm, respectively. Alternatively, post-column addition of sulfuric acid solution was used to decrease the determination limit. The recovery of methylbenzoquate, in a concentration range of 0.5-10 mg/kg, was 105.0 +/- 7.3%. The limi
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF AOAC INTERNATIONAL
ISSN
1060-3271
e-ISSN
—
Svazek periodika
88
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
673-678
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—