Chiral analysis by mass spectrometry using the kinetic method in flow systems
Popis výsledku v původním jazyce
Chiral analysis is an important task of analytical chemistry. Besides separation techniques, mass spectrometry can be applied in this field. One mass spectrometric approach is based on Cooks' kinetic method. The method was successfully applied in a static system in which the concentration of the analyte as well as the chiral selector solution was constant during the experiment. The application of the kinetic method in dynamic systems (changing concentration of analyte) is presented. Such systems allow the speeding up of the analytical process (flow injection analysis (FIA)) or the use of the kinetic method for chiral detection after liquid chromatographic separation. The influence of the concentration of the components of the chiral selector solution as well as its flow rate on the recognition of enantiomers was evaluated. A new procedure for correction for the differences between ratio of enantiomers in the liquid phase and their observed ratio in the gas phase is also described. A si
Název v anglickém jazyce
Chiral analysis by mass spectrometry using the kinetic method in flow systems
Popis výsledku anglicky
Chiral analysis is an important task of analytical chemistry. Besides separation techniques, mass spectrometry can be applied in this field. One mass spectrometric approach is based on Cooks' kinetic method. The method was successfully applied in a static system in which the concentration of the analyte as well as the chiral selector solution was constant during the experiment. The application of the kinetic method in dynamic systems (changing concentration of analyte) is presented. Such systems allow the speeding up of the analytical process (flow injection analysis (FIA)) or the use of the kinetic method for chiral detection after liquid chromatographic separation. The influence of the concentration of the components of the chiral selector solution as well as its flow rate on the recognition of enantiomers was evaluated. A new procedure for correction for the differences between ratio of enantiomers in the liquid phase and their observed ratio in the gas phase is also described. A si
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Mass Spectrometry
ISSN
1076-5174
e-ISSN
—
Svazek periodika
41
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
499-506
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—