Sterility testing by CE: A comparison of online preconcentration approaches in capillaries with greater internal diameters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F09%3A00010413" target="_blank" >RIV/61989592:15310/09:00010413 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11310/09:10000336
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sterility testing by CE: A comparison of online preconcentration approaches in capillaries with greater internal diameters
Popis výsledku v původním jazyce
Detection of microbial contamination is of critical importance in the medical and the food industry. Rapid tests for the absence or presence of viable microorganisms are in urgent demand. CE is a modem analytical technique that can be adapted for rapid screening of microbial contamination. However, the small dimensions of capillaries allow the introduction of only a small fraction of the sample, which can be problematic when examining large samples. In this article, we examine the possibilities of introducing larger sample volumes using capillaries with greater id together with different stacking techniques. The use of 0.32 mm id capillary and the injection of 60% of the capillary volume led to approximately 120-fold improvement of the injected samplevolume over the classical injection 5% of a 0.10-mm id capillary. The setup we described opens new possibilities in sterility testing using CE.
Název v anglickém jazyce
Sterility testing by CE: A comparison of online preconcentration approaches in capillaries with greater internal diameters
Popis výsledku anglicky
Detection of microbial contamination is of critical importance in the medical and the food industry. Rapid tests for the absence or presence of viable microorganisms are in urgent demand. CE is a modem analytical technique that can be adapted for rapid screening of microbial contamination. However, the small dimensions of capillaries allow the introduction of only a small fraction of the sample, which can be problematic when examining large samples. In this article, we examine the possibilities of introducing larger sample volumes using capillaries with greater id together with different stacking techniques. The use of 0.32 mm id capillary and the injection of 60% of the capillary volume led to approximately 120-fold improvement of the injected samplevolume over the classical injection 5% of a 0.10-mm id capillary. The setup we described opens new possibilities in sterility testing using CE.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ME%20895" target="_blank" >ME 895: Vývoj speciálních separačních médií s teplotně závislými vlastnostmi pro enantioselektivní separační systémy</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrophoresis
ISSN
0173-0835
e-ISSN
—
Svazek periodika
30
Číslo periodika v rámci svazku
22
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
7
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—