A novel fused-silica capillary dropping mercury electrode with long drop-time and its application on determination of critical micelle concentration
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F11%3A33117300" target="_blank" >RIV/61989592:15310/11:33117300 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.talanta.2010.12.050" target="_blank" >http://dx.doi.org/10.1016/j.talanta.2010.12.050</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2010.12.050" target="_blank" >10.1016/j.talanta.2010.12.050</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A novel fused-silica capillary dropping mercury electrode with long drop-time and its application on determination of critical micelle concentration
Popis výsledku v původním jazyce
A novel long drop time mercury electrode has been constructed from common fused-silica capillary (50um I.D., 360um E.D.). Proposed device provides reproducible mercury drops with typical lifetime 40-120 s. The electrode was used for a set of electrocapillary measurements aimed at determination of critical micelle concentration of anionic surfactants by a convection controlled drop-time technique. A critical micelle concentration of sodium dodecyl sulfate 5.6+-0.4mmolL?1 and 4.3+-0.4mmolL?1 were obtainedin 1mmolL?1 and 5mmolL?1 phosphate buffer (pH 7.0), respectively. The values were comparable to those obtained from conductometric measurements under the same conditions (7.0+-0.1mmolL?1 and 5.2+-0.1mmolL?1, respectively) and the difference was explained in accordance with theory of hemi-micelle formation.
Název v anglickém jazyce
A novel fused-silica capillary dropping mercury electrode with long drop-time and its application on determination of critical micelle concentration
Popis výsledku anglicky
A novel long drop time mercury electrode has been constructed from common fused-silica capillary (50um I.D., 360um E.D.). Proposed device provides reproducible mercury drops with typical lifetime 40-120 s. The electrode was used for a set of electrocapillary measurements aimed at determination of critical micelle concentration of anionic surfactants by a convection controlled drop-time technique. A critical micelle concentration of sodium dodecyl sulfate 5.6+-0.4mmolL?1 and 4.3+-0.4mmolL?1 were obtainedin 1mmolL?1 and 5mmolL?1 phosphate buffer (pH 7.0), respectively. The values were comparable to those obtained from conductometric measurements under the same conditions (7.0+-0.1mmolL?1 and 5.2+-0.1mmolL?1, respectively) and the difference was explained in accordance with theory of hemi-micelle formation.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
—
Svazek periodika
84
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
187-191
Kód UT WoS článku
000288342400030
EID výsledku v databázi Scopus
—