Fused-Silica Capillary Dropping Mercury Electrode for Electrocapillary Measurements
Popis výsledku v původním jazyce
A homemade fused-silica capillary dropping mercury electrode was used for the investigation of the adsorption behavior of a complex system by electrocapillary measurements. A mixture of soybean phospholipids, known as asolectin, was used for this purpose. The proposed setup with a fused-silica capillary electrode enables to observe aggregation and adsorption of asolectin aggregates at the mercury electrode surface and to determine the concentrations corresponding to the formation of asolectin micelles (critical micelle concentration, CMC) and liposomes (critical liposome concentration, CLC). Values of CMC (196.239.0 mg?L-1) and CLC (1360350 mg?L-1) were obtained from the dependence of drop time on the logarithm of asolectin concentration in phosphate buffer pH 7.0 within a concentration range from 1 to 50 mmol?L-1.
Název v anglickém jazyce
Fused-Silica Capillary Dropping Mercury Electrode for Electrocapillary Measurements
Popis výsledku anglicky
A homemade fused-silica capillary dropping mercury electrode was used for the investigation of the adsorption behavior of a complex system by electrocapillary measurements. A mixture of soybean phospholipids, known as asolectin, was used for this purpose. The proposed setup with a fused-silica capillary electrode enables to observe aggregation and adsorption of asolectin aggregates at the mercury electrode surface and to determine the concentrations corresponding to the formation of asolectin micelles (critical micelle concentration, CMC) and liposomes (critical liposome concentration, CLC). Values of CMC (196.239.0 mg?L-1) and CLC (1360350 mg?L-1) were obtained from the dependence of drop time on the logarithm of asolectin concentration in phosphate buffer pH 7.0 within a concentration range from 1 to 50 mmol?L-1.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electroanalysis
ISSN
1040-0397
e-ISSN
—
Svazek periodika
25
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
5
Strana od-do
174-178
Kód UT WoS článku
000313807600022
EID výsledku v databázi Scopus
—