Comparison of Reliability of the Eye Optic Disc Cup and Pallor Areas in Glaucoma Diagnostics
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F13%3A33144447" target="_blank" >RIV/61989592:15310/13:33144447 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of Reliability of the Eye Optic Disc Cup and Pallor Areas in Glaucoma Diagnostics
Popis výsledku v původním jazyce
The aim of this paper is to compare the glaucoma diagnostic reliability of two optic disc parameters: the relative cup area size determined by the Heidelberg retina tomography and the relative pallor area size determined by the proposed algorithm of theoptic disc image analysis. Both parameters were measured for 240 normal healthy eyes and 240 glaucomatous eyes. The diagnostic reliability of studied parameters were compared using normalized distance d of their statistical distributions obtained for normal healthy and glaucomatous eyes and by comparison of area sizes under their ROC (Receiver Operating Characteristic) curves. The normalized distances were 2.19 or 1.73 and the area sizes under ROC curves were 0.95 or 0.89 for relative cup or pallor areasize. Both considered relative parameters are significantly influenced by the glaucoma and can be used in its diagnostics. The designed pallor analysis is less diagnostic reliable than the analysis of the cup
Název v anglickém jazyce
Comparison of Reliability of the Eye Optic Disc Cup and Pallor Areas in Glaucoma Diagnostics
Popis výsledku anglicky
The aim of this paper is to compare the glaucoma diagnostic reliability of two optic disc parameters: the relative cup area size determined by the Heidelberg retina tomography and the relative pallor area size determined by the proposed algorithm of theoptic disc image analysis. Both parameters were measured for 240 normal healthy eyes and 240 glaucomatous eyes. The diagnostic reliability of studied parameters were compared using normalized distance d of their statistical distributions obtained for normal healthy and glaucomatous eyes and by comparison of area sizes under their ROC (Receiver Operating Characteristic) curves. The normalized distances were 2.19 or 1.73 and the area sizes under ROC curves were 0.95 or 0.89 for relative cup or pallor areasize. Both considered relative parameters are significantly influenced by the glaucoma and can be used in its diagnostics. The designed pallor analysis is less diagnostic reliable than the analysis of the cup
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Collegium Antropologicum
ISSN
0350-6134
e-ISSN
—
Svazek periodika
37
Číslo periodika v rámci svazku
S1
Stát vydavatele periodika
HR - Chorvatská republika
Počet stran výsledku
5
Strana od-do
59-63
Kód UT WoS článku
000318456800012
EID výsledku v databázi Scopus
—