Measurement efficiency of the modern spectroscopy systems is determined by the quality of the hardware used to acquire signals and by the software used to analyse data. Up-to-date systems process data with zero data amount loss. In this paper, a new concept of Mössbauer spectrometer used for material research is presented. Mössbauer spectrometer consists of spectrometric bench (radioactive source, velocity transducer, sample holder, and gamma-ray detector), measurement hardware, and control application.The Mössbauer effect is based on recoilless nuclear emission and resonant absorption of gamma-rays in the sample. The Mössbauer spectra acquisition is performed by gamma-ray intensity measurement together with radioactive source motion control causing the Doppler shift of the gamma-ray photons [1,2]. Mainly the synchronization between the detector signal acquisition and the source velocity motion processes is of crucial importance in this system. High precision execution of the detector
Název v anglickém jazyce
Mössbauer spectroscopy systém with increased performance and flexibility - utilization in materiál research
Popis výsledku anglicky
Measurement efficiency of the modern spectroscopy systems is determined by the quality of the hardware used to acquire signals and by the software used to analyse data. Up-to-date systems process data with zero data amount loss. In this paper, a new concept of Mössbauer spectrometer used for material research is presented. Mössbauer spectrometer consists of spectrometric bench (radioactive source, velocity transducer, sample holder, and gamma-ray detector), measurement hardware, and control application.The Mössbauer effect is based on recoilless nuclear emission and resonant absorption of gamma-rays in the sample. The Mössbauer spectra acquisition is performed by gamma-ray intensity measurement together with radioactive source motion control causing the Doppler shift of the gamma-ray photons [1,2]. Mainly the synchronization between the detector signal acquisition and the source velocity motion processes is of crucial importance in this system. High precision execution of the detector
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BC - Teorie a systémy řízení
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
19th International Conference on applied physics of condensed matter (APCOM 2013)
ISBN
978-80-227-3956-6
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
58-61
Název nakladatele
Slovenská technická univerzita
Místo vydání
Bratislava
Místo konání akce
Štrbské Pleso, Slovensko
Datum konání akce
19. 6. 2013
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—