HPLC-ED of low-molecular weight brominated phenols and tetrabromobisphenol A using pretreated carbon fiber microelectrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F14%3A33152563" target="_blank" >RIV/61989592:15310/14:33152563 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0039914014000241" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0039914014000241</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2014.01.013" target="_blank" >10.1016/j.talanta.2014.01.013</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
HPLC-ED of low-molecular weight brominated phenols and tetrabromobisphenol A using pretreated carbon fiber microelectrode
Popis výsledku v původním jazyce
Electrochemically pretreated carbon fiber microelectrode was used to develop a simple, fast and sensitive HPLC-ECD method for the determination of brominated phenols. In addition to simple mono-, di- and tri-bromophenols (4-bromophenol, 2,4-dibromophenol, 2,6-dibromophenol, 2,4,6-tri-bromophenol) the possibility of electrochemical detection of 3,3 ',5,5 '-tetrabromobisphenol A in oxidation mode is reported for the first time. The isocratic separation was achieved within 14 min using ternary mobile phaseconsisting of 50 mM-phosphate buffer (pH 3.5), acetonitrile and methanol (35/15/50, v/v), and detection potential of E = +1450 mV (vs. Ag/AgCl). The carbon fiber microelectrode permitted to use high anodic potentials (up to +1800 mV vs. Ag/AgCl), the optimum analytical response was achieved at +1450 mV vs. Ag/AgCl. The limits of detection (LOD) for the studied analytes were within the range of 1.856.6 ng mL(-1). The developed method was applied to determination of brominated phenols in
Název v anglickém jazyce
HPLC-ED of low-molecular weight brominated phenols and tetrabromobisphenol A using pretreated carbon fiber microelectrode
Popis výsledku anglicky
Electrochemically pretreated carbon fiber microelectrode was used to develop a simple, fast and sensitive HPLC-ECD method for the determination of brominated phenols. In addition to simple mono-, di- and tri-bromophenols (4-bromophenol, 2,4-dibromophenol, 2,6-dibromophenol, 2,4,6-tri-bromophenol) the possibility of electrochemical detection of 3,3 ',5,5 '-tetrabromobisphenol A in oxidation mode is reported for the first time. The isocratic separation was achieved within 14 min using ternary mobile phaseconsisting of 50 mM-phosphate buffer (pH 3.5), acetonitrile and methanol (35/15/50, v/v), and detection potential of E = +1450 mV (vs. Ag/AgCl). The carbon fiber microelectrode permitted to use high anodic potentials (up to +1800 mV vs. Ag/AgCl), the optimum analytical response was achieved at +1450 mV vs. Ag/AgCl. The limits of detection (LOD) for the studied analytes were within the range of 1.856.6 ng mL(-1). The developed method was applied to determination of brominated phenols in
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP206%2F12%2F0796" target="_blank" >GAP206/12/0796: Elektrody z uhlíkového mikrovlákna modifikované povrchovými úpravami a nanostrukturovanými kovovými povlaky jako vysoce citlivé HPLC-EC detektory</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
—
Svazek periodika
122
Číslo periodika v rámci svazku
MAY
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
7
Strana od-do
115-121
Kód UT WoS článku
000335636700018