Time differential Fe-57 Mossbauer spectrometer with unique 4 pi YAP:Ce 122.06 keV gamma-photon detector
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F16%3A33162154" target="_blank" >RIV/61989592:15310/16:33162154 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0168900216307069" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0168900216307069</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nima.2016.06.136" target="_blank" >10.1016/j.nima.2016.06.136</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Time differential Fe-57 Mossbauer spectrometer with unique 4 pi YAP:Ce 122.06 keV gamma-photon detector
Popis výsledku v původním jazyce
This paper presents a conceptually new design of the Fe-57 Time Differential Mossbauer Spectrometer (TDMS) with the gamma-photon detector optimized for registration of a radiation emitted in a maximum solid angle. A high detection efficiency of 80% in 4 pi region was achieved for 122.06 keV photons emitted from Co-57 source. Detector parameters have been optimized for the use in the Time Differential Mossbauer Spectroscopy where the high time resolution in range of 176-200 ns is highly required. Technical concept of the TDMS is based on the virtual instrumentation technique and uses fast digital oscilloscope. Performance and detector utilization have been clarified by decreasing the Mossbauer spectral line-width of K2MgFe(CN)(6) reference sample from 0.33 mm/s (integral mode) to 0.23 mm/s (time differential mode). This report also describes characterization and utilization of the detector together with additional electronic blocks and two-channel fast data-acquisition system construction.
Název v anglickém jazyce
Time differential Fe-57 Mossbauer spectrometer with unique 4 pi YAP:Ce 122.06 keV gamma-photon detector
Popis výsledku anglicky
This paper presents a conceptually new design of the Fe-57 Time Differential Mossbauer Spectrometer (TDMS) with the gamma-photon detector optimized for registration of a radiation emitted in a maximum solid angle. A high detection efficiency of 80% in 4 pi region was achieved for 122.06 keV photons emitted from Co-57 source. Detector parameters have been optimized for the use in the Time Differential Mossbauer Spectroscopy where the high time resolution in range of 176-200 ns is highly required. Technical concept of the TDMS is based on the virtual instrumentation technique and uses fast digital oscilloscope. Performance and detector utilization have been clarified by decreasing the Mossbauer spectral line-width of K2MgFe(CN)(6) reference sample from 0.33 mm/s (integral mode) to 0.23 mm/s (time differential mode). This report also describes characterization and utilization of the detector together with additional electronic blocks and two-channel fast data-acquisition system construction.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BE - Teoretická fyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0041" target="_blank" >EE2.3.30.0041: Podpora vytváření excelentních výzkumných týmů a intersektorální mobility na Univerzitě Palackého v Olomouci II.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments & Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors, and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Svazek periodika
832
Číslo periodika v rámci svazku
OCT
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
292-296
Kód UT WoS článku
000382256400034
EID výsledku v databázi Scopus
—