Electrokinetic preconcentration of magnetite core - carboxylic shell nanoparticles by capillary electrophoresis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F17%3A73583925" target="_blank" >RIV/61989592:15310/17:73583925 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0021967317304892" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0021967317304892</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2017.03.079" target="_blank" >10.1016/j.chroma.2017.03.079</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrokinetic preconcentration of magnetite core - carboxylic shell nanoparticles by capillary electrophoresis
Popis výsledku v původním jazyce
Online electrokinetic preconcentration of magnetite core/carboxylic shell nanoparticles (MNPs) was studied by capillary electrophoresis using reversed and suppressed electroosmotic flow (EOF). 50 mM sodium borate pH 9.5 was used as a background electrolyte. CTAB additive was used to reverse EOF and commercial polyvinylalcohol (PVA)-coated capillaries were used for EOF suppressed studies. Analyses in PVA-coated capillaries were more reproducible and therefore, the setup was further optimized in terms of water plug injection time, sample injection time, and voltage. Within the optimal conditions, the MNPs dispersed in water are electrokinetically loaded into BGE consisting of 50 mM sodium borate pH 9.5 using -10 kV for 120 s. In comparison with the hydrodynamic injection of 5 s by 50 mbar, the electrokinetic injection allows 860-fold preconcentration of MNPs
Název v anglickém jazyce
Electrokinetic preconcentration of magnetite core - carboxylic shell nanoparticles by capillary electrophoresis
Popis výsledku anglicky
Online electrokinetic preconcentration of magnetite core/carboxylic shell nanoparticles (MNPs) was studied by capillary electrophoresis using reversed and suppressed electroosmotic flow (EOF). 50 mM sodium borate pH 9.5 was used as a background electrolyte. CTAB additive was used to reverse EOF and commercial polyvinylalcohol (PVA)-coated capillaries were used for EOF suppressed studies. Analyses in PVA-coated capillaries were more reproducible and therefore, the setup was further optimized in terms of water plug injection time, sample injection time, and voltage. Within the optimal conditions, the MNPs dispersed in water are electrokinetically loaded into BGE consisting of 50 mM sodium borate pH 9.5 using -10 kV for 120 s. In comparison with the hydrodynamic injection of 5 s by 50 mbar, the electrokinetic injection allows 860-fold preconcentration of MNPs
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography A: Symposium Volumes
ISSN
0021-9673
e-ISSN
—
Svazek periodika
1499
Číslo periodika v rámci svazku
MAY
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
5
Strana od-do
217-221
Kód UT WoS článku
000401394200024
EID výsledku v databázi Scopus
—