Immobilized Fluorescent Probes for Simultaneous Multiple Protease Detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F21%3A73608446" target="_blank" >RIV/61989592:15310/21:73608446 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.mdpi.com/2227-9040/9/6/119/htm" target="_blank" >https://www.mdpi.com/2227-9040/9/6/119/htm</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/chemosensors9060119" target="_blank" >10.3390/chemosensors9060119</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Immobilized Fluorescent Probes for Simultaneous Multiple Protease Detection
Popis výsledku v původním jazyce
A new concept for simultaneous detection of two model proteases based on immobilized fluorescently labelled peptides was developed and evaluated. Each probe was composed of a carrier modified by poly(ethylene glycol) (PEG) chains, a specifically cleavable linker, and a fluorescent dye incorporated in the peptide tail. Based on a single excitation-double emission fluorescence response of liberated fluorophores caused by enzymatic cleavage, the presence of a single or both proteases in a mixture was unambiguously determined in an experimentally established concentration range. Among the tested solid supports, Rink Amide PEGA resin was recognized as the most suitable choice from the perspective of on-resin enzyme assays.
Název v anglickém jazyce
Immobilized Fluorescent Probes for Simultaneous Multiple Protease Detection
Popis výsledku anglicky
A new concept for simultaneous detection of two model proteases based on immobilized fluorescently labelled peptides was developed and evaluated. Each probe was composed of a carrier modified by poly(ethylene glycol) (PEG) chains, a specifically cleavable linker, and a fluorescent dye incorporated in the peptide tail. Based on a single excitation-double emission fluorescence response of liberated fluorophores caused by enzymatic cleavage, the presence of a single or both proteases in a mixture was unambiguously determined in an experimentally established concentration range. Among the tested solid supports, Rink Amide PEGA resin was recognized as the most suitable choice from the perspective of on-resin enzyme assays.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10401 - Organic chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA19-23972S" target="_blank" >GA19-23972S: Multi-FRET fluorescenční sondy aktivované hydrolasami</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemosensors
ISSN
2227-9040
e-ISSN
—
Svazek periodika
9
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
13
Strana od-do
"119-1"-"119-13"
Kód UT WoS článku
000665373600001
EID výsledku v databázi Scopus
2-s2.0-85107462035