Improvement of gas proportional counter performance by registration krypton and argon escape peaks in Mössbauer spectroscopy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F22%3A73609559" target="_blank" >RIV/61989592:15310/22:73609559 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0168583X2100392X" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0168583X2100392X</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.nimb.2021.11.017" target="_blank" >10.1016/j.nimb.2021.11.017</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Improvement of gas proportional counter performance by registration krypton and argon escape peaks in Mössbauer spectroscopy
Popis výsledku v původním jazyce
Proportional gas counters are commonly used in the 57Fe Mössbauer spectroscopy for their good energy resolution and insensitivity to magnetic field. However, their counting rate is usually limited by relatively long dead time. This paper demonstrates a detection performance improving technique by registration Kα escape peaks coupled together with main full energy peaks. The validity of using both peaks was verified by transmission and conversion X-rays Mössbauer spectra recording, while using proportional gas counters filled with pure krypton and a mixture of argon and methane. The influence of this method on the resulted α-Fe Mössbauer spectra was studied in a view of resonance effect, energy resolution, spectra baseline, and statistical quality. The presented technique showed that the counting rate of Mössbauer spectra accumulation was increased by 95% while using pure krypton, whereas by using a mixture of argon and methane, the counting rate reached an increase of 27%.
Název v anglickém jazyce
Improvement of gas proportional counter performance by registration krypton and argon escape peaks in Mössbauer spectroscopy
Popis výsledku anglicky
Proportional gas counters are commonly used in the 57Fe Mössbauer spectroscopy for their good energy resolution and insensitivity to magnetic field. However, their counting rate is usually limited by relatively long dead time. This paper demonstrates a detection performance improving technique by registration Kα escape peaks coupled together with main full energy peaks. The validity of using both peaks was verified by transmission and conversion X-rays Mössbauer spectra recording, while using proportional gas counters filled with pure krypton and a mixture of argon and methane. The influence of this method on the resulted α-Fe Mössbauer spectra was studied in a view of resonance effect, energy resolution, spectra baseline, and statistical quality. The presented technique showed that the counting rate of Mössbauer spectra accumulation was increased by 95% while using pure krypton, whereas by using a mixture of argon and methane, the counting rate reached an increase of 27%.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
<a href="/cs/project/EF17_049%2F0008408" target="_blank" >EF17_049/0008408: Hydrodynamický design čerpadel</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS
ISSN
0168-583X
e-ISSN
1872-9584
Svazek periodika
511
Číslo periodika v rámci svazku
JAN
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
9
Strana od-do
75-83
Kód UT WoS článku
000744227000008
EID výsledku v databázi Scopus
2-s2.0-85120170339