Popis výsledku v původním jazyce
A novel, cheap and easy-to-construct device and a simple method for partition coefficient determination in liposome/water system based on modified equilibrium dialysis have been developed. The device consists of two vials separated by a semi-permeable membrane, through which the free form of a low molecular weight sub-stance is transported by shaking assisted diffusion. Five test substances, eugenol, carvacrol, thymol, 4-hydroxy-benzyl alcohol (4-HBA) and butylparaben were analyzed after equilibration in aqueous phase by three methods, HPLC-UV, GC-MS and DPV with comparable results. This shows the possibility of using the proposed method in any laboratory with any equipment capable of analyzing the substance under study. The liposome/water partition coefficients (log Pl/w) determined for eugenol (2.39), thymol (2.83), carvacrol (2.78) and butylparaben (3.30) are consistent with previously published data. A strong effect of NaCl on the liposome/water partition coefficient was observed. The value of log Pl/w = 1.06 determined for 4-HBA in the presence of 0.15 mol L-1 NaCl in the partitioning liposomal system was considerably lower than in the absence of the salt (log Pl/w = 2.06). The developed method was used to determine the partition coefficient of morphine in liposome/water system without NaCl (log Pl/w = 2.65) under given conditions.
Název v anglickém jazyce
A novel device for the determination of liposome/water partition coefficients
Popis výsledku anglicky
A novel, cheap and easy-to-construct device and a simple method for partition coefficient determination in liposome/water system based on modified equilibrium dialysis have been developed. The device consists of two vials separated by a semi-permeable membrane, through which the free form of a low molecular weight sub-stance is transported by shaking assisted diffusion. Five test substances, eugenol, carvacrol, thymol, 4-hydroxy-benzyl alcohol (4-HBA) and butylparaben were analyzed after equilibration in aqueous phase by three methods, HPLC-UV, GC-MS and DPV with comparable results. This shows the possibility of using the proposed method in any laboratory with any equipment capable of analyzing the substance under study. The liposome/water partition coefficients (log Pl/w) determined for eugenol (2.39), thymol (2.83), carvacrol (2.78) and butylparaben (3.30) are consistent with previously published data. A strong effect of NaCl on the liposome/water partition coefficient was observed. The value of log Pl/w = 1.06 determined for 4-HBA in the presence of 0.15 mol L-1 NaCl in the partitioning liposomal system was considerably lower than in the absence of the salt (log Pl/w = 2.06). The developed method was used to determine the partition coefficient of morphine in liposome/water system without NaCl (log Pl/w = 2.65) under given conditions.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/GA20-07350S" target="_blank" >GA20-07350S: Elektrochemické a analytické aspekty transportu návykových a psychotropních látek přes modelové biologické bariery</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
TALANTA
ISSN
0039-9140
e-ISSN
1873-3573
Svazek periodika
269
Číslo periodika v rámci svazku
MAR
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
"125434-1"-"125434-8"
Kód UT WoS článku
001165956200001
EID výsledku v databázi Scopus
2-s2.0-85181583919