Analysis of 3-quinuclidinol derivatives by capillary electrophoresis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15410%2F03%3A00001318" target="_blank" >RIV/61989592:15410/03:00001318 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of 3-quinuclidinol derivatives by capillary electrophoresis
Popis výsledku v původním jazyce
Capillary electrophoresis with indirect UV detection was applied to the analysis of a mixture of 3-quinuclidinol and its four quaternary derivatives (N-methyl, N-ethyl, N-propyl, and N-isopropyl derivative). 10 mM imidazole acetate buffer, pH = 4.0 offers suitable detection sensitivity (LOD = 1 mumol L-1) and permits separation of the mixture except for the pair 3-quinuclidinol- N-methyl derivative. The separation of all analytes was achieved on addition of 15 mmol L-1 beta-cyclodextrin or 25% (w/w) polyethylene glycol 2000 to the background electrolyte. The optimized method was employed for the analysis of pond water spiked with these analytes. Actual ionic mobilities of the studied compounds were measured using mobility standards (potassium, sodium,tetramethyl- and tetrabutylammonium). The migration index was derived as another identification parameter based on migration data and the precision of the obtained values is discussed in brief.
Název v anglickém jazyce
Analysis of 3-quinuclidinol derivatives by capillary electrophoresis
Popis výsledku anglicky
Capillary electrophoresis with indirect UV detection was applied to the analysis of a mixture of 3-quinuclidinol and its four quaternary derivatives (N-methyl, N-ethyl, N-propyl, and N-isopropyl derivative). 10 mM imidazole acetate buffer, pH = 4.0 offers suitable detection sensitivity (LOD = 1 mumol L-1) and permits separation of the mixture except for the pair 3-quinuclidinol- N-methyl derivative. The separation of all analytes was achieved on addition of 15 mmol L-1 beta-cyclodextrin or 25% (w/w) polyethylene glycol 2000 to the background electrolyte. The optimized method was employed for the analysis of pond water spiked with these analytes. Actual ionic mobilities of the studied compounds were measured using mobility standards (potassium, sodium,tetramethyl- and tetrabutylammonium). The migration index was derived as another identification parameter based on migration data and the precision of the obtained values is discussed in brief.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2003
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Separation Science
ISSN
1615-9306
e-ISSN
—
Svazek periodika
26
Číslo periodika v rámci svazku
8
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
709-714
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—