Hodnocení fixačních poloh těla při diagnostice držení těla diagnostickým systémem DTP-2
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15510%2F06%3A00003440" target="_blank" >RIV/61989592:15510/06:00003440 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of the fixation of body position for posture diagnostics by means of the diagnostic system DTP-2 [CD]
Popis výsledku v původním jazyce
The reliability of posture diagnostics done by means of the diagnostic system DTP-2 is discussed in this contribution. Titubation of the proband is one of factors that decreases the reliability of posture diagnostics. This problem has not been studied indetail yet, therefore the results of a study that quantifies the influence of proband titubation is presented. The titubation was quantified in three chosen fixation positions: A - the loose position, B - the position with partial fixation by means of the upper extremities, C - the position with the trunk fixation by means of a wall. The fixation positions A and C have the most suitable properties for an application in clinical practice. The fixation position A has the lowest reliability because a proband titubation is not decreased but on the other hand the spine curve is not affected by systematic error. Furthermore, the values of unaffected titubation expressed by means of the standard deviations can be used for the assessment of a
Název v anglickém jazyce
Assessment of the fixation of body position for posture diagnostics by means of the diagnostic system DTP-2 [CD]
Popis výsledku anglicky
The reliability of posture diagnostics done by means of the diagnostic system DTP-2 is discussed in this contribution. Titubation of the proband is one of factors that decreases the reliability of posture diagnostics. This problem has not been studied indetail yet, therefore the results of a study that quantifies the influence of proband titubation is presented. The titubation was quantified in three chosen fixation positions: A - the loose position, B - the position with partial fixation by means of the upper extremities, C - the position with the trunk fixation by means of a wall. The fixation positions A and C have the most suitable properties for an application in clinical practice. The fixation position A has the lowest reliability because a proband titubation is not decreased but on the other hand the spine curve is not affected by systematic error. Furthermore, the values of unaffected titubation expressed by means of the standard deviations can be used for the assessment of a
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
—
Místo vydání
Brno
Název nakladatele resp. objednatele
Vysoké učení technické
Verze
—
Identifikační číslo nosiče
—