Charakteristiky vybraných fixačních poloh při diagnostice držení těla systémem DTP-2
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15510%2F06%3A00003445" target="_blank" >RIV/61989592:15510/06:00003445 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Features of chosen fixation positions for the posture diagnostics by means of the system DTP-2
Popis výsledku v původním jazyce
Titubation of the proband is one of factors that decreases the reliability of posture diagnostics. In this study, the titubation in three chosen fixation positions was quantified: A - the loose position, B - the position with partial fixation by means ofthe upper extremities, C - the position with the trunk fixation by means of a wall. This study included n = 60 probands. Each proband was measured five times by means of the diagnostic system DTP-2. The average spine curve and standard deviation were calculated for each fixation position. The increasing degree of fixation A -> B -> C decreases the value of standard deviations in the lateral direction 3.0 -> 1.7 -> 1.6 [mm] and in the ventral direction 3.9 -> 2.4 -> 1.4 [mm]. The fixation does not affect the values in the cranial direction. The fixation positions A and C have the most suitable properties for an application in clinical practice. The fixation position A has the lowest reliability but the spine curve is not affected by s
Název v anglickém jazyce
Features of chosen fixation positions for the posture diagnostics by means of the system DTP-2
Popis výsledku anglicky
Titubation of the proband is one of factors that decreases the reliability of posture diagnostics. In this study, the titubation in three chosen fixation positions was quantified: A - the loose position, B - the position with partial fixation by means ofthe upper extremities, C - the position with the trunk fixation by means of a wall. This study included n = 60 probands. Each proband was measured five times by means of the diagnostic system DTP-2. The average spine curve and standard deviation were calculated for each fixation position. The increasing degree of fixation A -> B -> C decreases the value of standard deviations in the lateral direction 3.0 -> 1.7 -> 1.6 [mm] and in the ventral direction 3.9 -> 2.4 -> 1.4 [mm]. The fixation does not affect the values in the cranial direction. The fixation positions A and C have the most suitable properties for an application in clinical practice. The fixation position A has the lowest reliability but the spine curve is not affected by s
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
FS - Lékařská zařízení, přístroje a vybavení
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
5th international conference Movement and health - proceedings
ISBN
83-60691-05-3
ISSN
—
e-ISSN
—
Počet stran výsledku
637
Strana od-do
479-485
Název nakladatele
Opole University of Technology
Místo vydání
Opole
Místo konání akce
—
Datum konání akce
—
Typ akce podle státní příslušnosti
—
Kód UT WoS článku
—