Fibroblast growth factor-19: Development, analytical characterization and clinical evaluation of a New ELISA Test
Popis výsledku v původním jazyce
Background: Fibroblast growth factor 19 (FGF-19) is a potent metabolic regulator which influences glucose and lipid homeostasis. Aim: To develop an ELISA assay for measuring FGF-19 in human serum, and to investigate its concentrations in healthy volunteers and patients suffering from the metabolic syndrome. Material and Methods: A sandwich ELISA method was developed for quantitative determination of human FGF-19 in serum samples. Blood pressure, waist circumference, FGF-21 serum levels, serum cholesterol, triacylglycerols, HDL-cholesterol, LDL-cholesterol, insulin, glucose, adiponectin, uric acid, creatinine, hs-CRP and calculated BMI and Quicki insulin sensitivity index were measured in 153 healthy volunteers and in 66 persons with the metabolic syndrome. Results: Sex or age did not influence FGF-19 serum concentrations in the healthy volunteers. Probands with the metabolic syndrome had had 65% lower FGF-19 serum values than the healthy ones (medians 158.6 vs. 242.4 ng/L; p<0.01). FGF
Název v anglickém jazyce
Fibroblast growth factor-19: Development, analytical characterization and clinical evaluation of a New ELISA Test
Popis výsledku anglicky
Background: Fibroblast growth factor 19 (FGF-19) is a potent metabolic regulator which influences glucose and lipid homeostasis. Aim: To develop an ELISA assay for measuring FGF-19 in human serum, and to investigate its concentrations in healthy volunteers and patients suffering from the metabolic syndrome. Material and Methods: A sandwich ELISA method was developed for quantitative determination of human FGF-19 in serum samples. Blood pressure, waist circumference, FGF-21 serum levels, serum cholesterol, triacylglycerols, HDL-cholesterol, LDL-cholesterol, insulin, glucose, adiponectin, uric acid, creatinine, hs-CRP and calculated BMI and Quicki insulin sensitivity index were measured in 153 healthy volunteers and in 66 persons with the metabolic syndrome. Results: Sex or age did not influence FGF-19 serum concentrations in the healthy volunteers. Probands with the metabolic syndrome had had 65% lower FGF-19 serum values than the healthy ones (medians 158.6 vs. 242.4 ng/L; p<0.01). FGF
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
ED - Fyziologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Scandinavian Journal of Clinical and Laboratory Investigation
ISSN
0036-5513
e-ISSN
—
Svazek periodika
68
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—