Variability of kinetic variables during gait in unilateral transtibial amputees
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15510%2F12%3A33138750" target="_blank" >RIV/61989592:15510/12:33138750 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1177/0309364612439572" target="_blank" >http://dx.doi.org/10.1177/0309364612439572</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1177/0309364612439572" target="_blank" >10.1177/0309364612439572</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Variability of kinetic variables during gait in unilateral transtibial amputees
Popis výsledku v původním jazyce
Background: Prosthetic gait increases demands on stability. Some variability measures can be used to investigate the stability of movement for prosthetic feet. Objectives: The purpose of this study was to determine the influence of the prosthetic foot onground reaction force variability for transtibial amputee gait. Study Design: Comparative analysis. Methods: Eleven male unilateral transtibial amputees participated in this study. Each subject walked at self-selected speed with both conventional (SACH)and energy storing (Sureflex) feet. Time and ground reaction force variables and their coefficients of variation were calculated for each foot type and limb. Results: Mediolateral force variables had high variability for all conditions. The Sureflex hada larger variability than the SACH foot for the braking peak (p { 0.05), which may have been caused by gait instability after the heel strike. There were significant differences between intact and prosthetic limbs in total loading (force
Název v anglickém jazyce
Variability of kinetic variables during gait in unilateral transtibial amputees
Popis výsledku anglicky
Background: Prosthetic gait increases demands on stability. Some variability measures can be used to investigate the stability of movement for prosthetic feet. Objectives: The purpose of this study was to determine the influence of the prosthetic foot onground reaction force variability for transtibial amputee gait. Study Design: Comparative analysis. Methods: Eleven male unilateral transtibial amputees participated in this study. Each subject walked at self-selected speed with both conventional (SACH)and energy storing (Sureflex) feet. Time and ground reaction force variables and their coefficients of variation were calculated for each foot type and limb. Results: Mediolateral force variables had high variability for all conditions. The Sureflex hada larger variability than the SACH foot for the braking peak (p { 0.05), which may have been caused by gait instability after the heel strike. There were significant differences between intact and prosthetic limbs in total loading (force
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Prosthetics and orthotics international
ISSN
0309-3646
e-ISSN
—
Svazek periodika
36
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
6
Strana od-do
225-230
Kód UT WoS článku
000305568900010
EID výsledku v databázi Scopus
—