FI-CE systém s CCD detektcí pro automatické DOI dávkování
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F04%3A00000822" target="_blank" >RIV/62156489:43210/04:00000822 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Flow Injection-Capillary Electrophoresis System with High Voltage Contactless Conductivity Detection for Automated Dual Opposite End Injection.
Popis výsledku v původním jazyce
The system comprises two flow injection-capillary electrophoresis interfaces into which the opposite ends of the separation capillary are inserted. The electrolyte solution flows through both interfaces by use of hydrostatic pressure. The injection of the samples into the electrolyte flow is accomplished by a rotary-type chromatographic valve at the grounded side and by a pinch-valve injector at the high voltage side that provides sufficient isolation from the high electric field. The system allows a fully automated dual-injection sequence of samples from both capillary ends and simultaneous electrophoretic separation of anions and cations in the samples. The analytes are detected by a high voltage contactless conductometric detector positioned approximately in the middle of the separation capillary. The parameters of the system were evaluated. The repeatability of the flow injection-capillary electrophoresis system for the simultaneous determination of anions and cations was evaluated
Název v anglickém jazyce
A Flow Injection-Capillary Electrophoresis System with High Voltage Contactless Conductivity Detection for Automated Dual Opposite End Injection.
Popis výsledku anglicky
The system comprises two flow injection-capillary electrophoresis interfaces into which the opposite ends of the separation capillary are inserted. The electrolyte solution flows through both interfaces by use of hydrostatic pressure. The injection of the samples into the electrolyte flow is accomplished by a rotary-type chromatographic valve at the grounded side and by a pinch-valve injector at the high voltage side that provides sufficient isolation from the high electric field. The system allows a fully automated dual-injection sequence of samples from both capillary ends and simultaneous electrophoretic separation of anions and cations in the samples. The analytes are detected by a high voltage contactless conductometric detector positioned approximately in the middle of the separation capillary. The parameters of the system were evaluated. The repeatability of the flow injection-capillary electrophoresis system for the simultaneous determination of anions and cations was evaluated
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Electrophoresis
ISSN
0173-0835
e-ISSN
—
Svazek periodika
25
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
8
Strana od-do
35-42