An analysis of avidin, biotin and their interaction at attomole levels by voltammetric and chromatographic techniques
Popis výsledku v původním jazyce
The electroanalytical determination of avidin in solution, in a carbon paste, and in a transgenic maize extract was performed in acidic medium at a carbon paste electrode (CPE). The oxidative voltammetric signal resulting from the presence of tyrosine and tryptophan in avidin was observed using square-wave voltammetry. The process could be used to determine avidin concentrations up to 3 fM (100 amol in 3 mu l drop) in solution, 700 fM (174 fmol in 250 mu l solution) in an avidin-modified electrode, and174 nM in a maize seed extract. In the case of the avidin-modified CPE, several parameters were studied in order to optimize the measurements, such as electrode accumulation time, composition of the avidin-modified CPE, and the elution time of avidin. Inaddition, the avidin-modified electrode was used to detect biotin in solution (the detection limit was 7.6 pmol in a 6 mu l drop) and to detect biotin in a pharmaceutical drug after various solvent extraction procedures. Comparable studi
Název v anglickém jazyce
An analysis of avidin, biotin and their interaction at attomole levels by voltammetric and chromatographic techniques
Popis výsledku anglicky
The electroanalytical determination of avidin in solution, in a carbon paste, and in a transgenic maize extract was performed in acidic medium at a carbon paste electrode (CPE). The oxidative voltammetric signal resulting from the presence of tyrosine and tryptophan in avidin was observed using square-wave voltammetry. The process could be used to determine avidin concentrations up to 3 fM (100 amol in 3 mu l drop) in solution, 700 fM (174 fmol in 250 mu l solution) in an avidin-modified electrode, and174 nM in a maize seed extract. In the case of the avidin-modified CPE, several parameters were studied in order to optimize the measurements, such as electrode accumulation time, composition of the avidin-modified CPE, and the elution time of avidin. Inaddition, the avidin-modified electrode was used to detect biotin in solution (the detection limit was 7.6 pmol in a 6 mu l drop) and to detect biotin in a pharmaceutical drug after various solvent extraction procedures. Comparable studi
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical and bioanalytical chemistry
ISSN
1618-2642
e-ISSN
—
Svazek periodika
381
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
12
Strana od-do
1167-1178
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—