Calculation of cooling curve of the combustion boiler refractories lining with use of an experimental device
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F12%3A00187735" target="_blank" >RIV/62156489:43210/12:00187735 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Calculation of cooling curve of the combustion boiler refractories lining with use of an experimental device
Popis výsledku v původním jazyce
The aim of the work was modeling of cooling process dynamics of a combustion boiler and designing of the method, which is suitable for calculation of cooling time in a large scale of temperature. Methods were verified with the use of referential combustion boiler with heat output of 130 kW. This boiler burned mixture of waste sawdust and shavings originating in the course of production of wooden furniture. For these purposes specialized experimental device has been used. Cooling curves were measured ininterval from 380 °C to 50 °C and were described by using of polynomial function. The cooling time was calculated by using of polynomial function in full temperature scale for cooling of combustion boiler refractories lining, from 700 °C to 50 °C.
Název v anglickém jazyce
Calculation of cooling curve of the combustion boiler refractories lining with use of an experimental device
Popis výsledku anglicky
The aim of the work was modeling of cooling process dynamics of a combustion boiler and designing of the method, which is suitable for calculation of cooling time in a large scale of temperature. Methods were verified with the use of referential combustion boiler with heat output of 130 kW. This boiler burned mixture of waste sawdust and shavings originating in the course of production of wooden furniture. For these purposes specialized experimental device has been used. Cooling curves were measured ininterval from 380 °C to 50 °C and were described by using of polynomial function. The cooling time was calculated by using of polynomial function in full temperature scale for cooling of combustion boiler refractories lining, from 700 °C to 50 °C.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BJ - Termodynamika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Universitatis Agriculturae et Silviculturae Mendelianae Brunensis
ISSN
1211-8516
e-ISSN
—
Svazek periodika
LX
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
111-116
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—