Carbofuran assay using gelatin based biosensor with acetylcholinesterase as a recognition element
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F13%3A00199025" target="_blank" >RIV/62156489:43210/13:00199025 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/60162694:G44__/13:43874959 RIV/00216305:26620/13:PU103103 RIV/25766872:_____/12:#0000083
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Carbofuran assay using gelatin based biosensor with acetylcholinesterase as a recognition element
Popis výsledku v původním jazyce
Carbofuran is a neurotoxic pesticide acting as an inhibitor of enzyme acetylcholinesterase (AChE). The fact that carbofuran is able to inhibit AChE can be used for its assay using an appropriate sensor. Here, electrochemical biosensor having immobilizedAChE and using acetylthiocholine as substrate was performed. The biosensor was consisted from a layer containing electric eel AChE and screen printed sensors. AChE was immobilized into gelatin membrane. The immobilization procedure was optimized considering temperature of drying and concentration of gelatin in mixture. Long term stability and interference of organic solvent was done as well. In the final experiment, carbofuran was assayed using the prepared biosensor. Limit of detection 5.01 x 10-10 mol/l (0.111 ng/ml) was achieved.
Název v anglickém jazyce
Carbofuran assay using gelatin based biosensor with acetylcholinesterase as a recognition element
Popis výsledku anglicky
Carbofuran is a neurotoxic pesticide acting as an inhibitor of enzyme acetylcholinesterase (AChE). The fact that carbofuran is able to inhibit AChE can be used for its assay using an appropriate sensor. Here, electrochemical biosensor having immobilizedAChE and using acetylthiocholine as substrate was performed. The biosensor was consisted from a layer containing electric eel AChE and screen printed sensors. AChE was immobilized into gelatin membrane. The immobilization procedure was optimized considering temperature of drying and concentration of gelatin in mixture. Long term stability and interference of organic solvent was done as well. In the final experiment, carbofuran was assayed using the prepared biosensor. Limit of detection 5.01 x 10-10 mol/l (0.111 ng/ml) was achieved.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
O - Projekt operacniho programu
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Electrochemical Science
ISSN
1452-3981
e-ISSN
—
Svazek periodika
8
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
RS - Srbská republika
Počet stran výsledku
9
Strana od-do
71-79
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—