Voltammetric Biosensor Based on Acetylcholinesterase and Different Immobilization Protocols: A Simple Tool for Toxic Organophosphate Assay
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16270%2F11%3A43870596" target="_blank" >RIV/62157124:16270/11:43870596 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11160/11:10118898
Výsledek na webu
<a href="http://dx.doi.org/10.1080/00032719.2010.511745" target="_blank" >http://dx.doi.org/10.1080/00032719.2010.511745</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/00032719.2010.511745" target="_blank" >10.1080/00032719.2010.511745</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltammetric Biosensor Based on Acetylcholinesterase and Different Immobilization Protocols: A Simple Tool for Toxic Organophosphate Assay
Popis výsledku v původním jazyce
The present study is aimed at construction of biosensors consisting of a screen printed sensor with a platinum working electrode and immobilized acetylcholinesterase (AChE) as a biorecognition element. Several immobilization protocols such as precipitation with glutaraldehyde, immobilization onto spherical graphite microparticles, sorption, interception into gelatin, and sol-gel were used in order to construct biosensors suitable for practical performance. The activity of AChE was evaluated by means ofvoltammetric oxidation of thiocholine originating from acetylthiocholine. Square wave and cyclic voltammetry were used throughout the experiments. Suitability of the constructed biosensors was evaluated using the toxic organophosphate diisopropylfluorophosphate.
Název v anglickém jazyce
Voltammetric Biosensor Based on Acetylcholinesterase and Different Immobilization Protocols: A Simple Tool for Toxic Organophosphate Assay
Popis výsledku anglicky
The present study is aimed at construction of biosensors consisting of a screen printed sensor with a platinum working electrode and immobilized acetylcholinesterase (AChE) as a biorecognition element. Several immobilization protocols such as precipitation with glutaraldehyde, immobilization onto spherical graphite microparticles, sorption, interception into gelatin, and sol-gel were used in order to construct biosensors suitable for practical performance. The activity of AChE was evaluated by means ofvoltammetric oxidation of thiocholine originating from acetylthiocholine. Square wave and cyclic voltammetry were used throughout the experiments. Suitability of the constructed biosensors was evaluated using the toxic organophosphate diisopropylfluorophosphate.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical Letters
ISSN
0003-2719
e-ISSN
—
Svazek periodika
44
Číslo periodika v rámci svazku
7
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
1254-1264
Kód UT WoS článku
000291643600008
EID výsledku v databázi Scopus
—