Experimental chambers for automatic fumigation of plants with elevated CO2 concentration and drought stress induction with the use of recirculation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F13%3A43908901" target="_blank" >RIV/62156489:43210/13:43908901 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62156489:43410/13:43908901
Výsledek na webu
<a href="https://mnet.mendelu.cz/mendelnet2013/mnet_2013_full.pdf" target="_blank" >https://mnet.mendelu.cz/mendelnet2013/mnet_2013_full.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental chambers for automatic fumigation of plants with elevated CO2 concentration and drought stress induction with the use of recirculation
Popis výsledku v původním jazyce
Chambers designed for experimental station Domaninek (near Bystrice nad Pernstejnem), allow precise control of the CO2 concentration in the atmosphere inside the chamber using a ventilation system with injection of gaseous CO2 and feedback control basedon the ongoing continuous measurement of CO2 from individual chambers using an infrared analyzer. Ventilation of chamber is adjustable in various intensities by opening roof lamellas, and power control of the fan. This system allows maintaining a minimumtemperature difference between outside and inside the chamber. The chambers are equipped with unique recirculation system which minimizes CO2 consumption in conditions with minimal heating the air inside the chamber (cloudy, morning, evening). Control of chambers is performed automatically based on signals from the sensors and analyzers using specially developed software.
Název v anglickém jazyce
Experimental chambers for automatic fumigation of plants with elevated CO2 concentration and drought stress induction with the use of recirculation
Popis výsledku anglicky
Chambers designed for experimental station Domaninek (near Bystrice nad Pernstejnem), allow precise control of the CO2 concentration in the atmosphere inside the chamber using a ventilation system with injection of gaseous CO2 and feedback control basedon the ongoing continuous measurement of CO2 from individual chambers using an infrared analyzer. Ventilation of chamber is adjustable in various intensities by opening roof lamellas, and power control of the fan. This system allows maintaining a minimumtemperature difference between outside and inside the chamber. The chambers are equipped with unique recirculation system which minimizes CO2 consumption in conditions with minimal heating the air inside the chamber (cloudy, morning, evening). Control of chambers is performed automatically based on signals from the sensors and analyzers using specially developed software.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
MendelNet 2013: Proceedings of International PhD Students Conference
ISBN
978-80-7375-908-7
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
852-856
Název nakladatele
Mendelova univerzita v Brně
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
20. 11. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000366464800150