Electrochemical detection of Cr(III) ion using activated glassy carbon electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F15%3A43906991" target="_blank" >RIV/62156489:43210/15:43906991 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Electrochemical detection of Cr(III) ion using activated glassy carbon electrode
Popis výsledku v původním jazyce
Heavy metals are attracting more attention in environmental, toxicological, pharma-ceutical and biomedical analysis. Among those, the detection of chromium is of particular interest owing to the high toxicity of it. In aqueous solution, the stable oxidation states of chromium are Cr (III) and Cr (VI). Cr (III) is considered less toxic than Cr (VI) and even essential to human health in trace concentration. However, higher concentration of Cr (III) can cause adverse effects because of its high capabilityof coordinating with various orga-nic compounds, resulting in inhibiting some metallic-enzyme systems. Electrochemical methods are chosen for analytical purpose, as they are reliable, sensitive and requiring less expensive equipment. In this study, activated glassy carbon electrode was used to determine Cr (III) ion. Limit of detection (LOD) and limit of quantification (LOQ) were also investigated in the present study.
Název v anglickém jazyce
Electrochemical detection of Cr(III) ion using activated glassy carbon electrode
Popis výsledku anglicky
Heavy metals are attracting more attention in environmental, toxicological, pharma-ceutical and biomedical analysis. Among those, the detection of chromium is of particular interest owing to the high toxicity of it. In aqueous solution, the stable oxidation states of chromium are Cr (III) and Cr (VI). Cr (III) is considered less toxic than Cr (VI) and even essential to human health in trace concentration. However, higher concentration of Cr (III) can cause adverse effects because of its high capabilityof coordinating with various orga-nic compounds, resulting in inhibiting some metallic-enzyme systems. Electrochemical methods are chosen for analytical purpose, as they are reliable, sensitive and requiring less expensive equipment. In this study, activated glassy carbon electrode was used to determine Cr (III) ion. Limit of detection (LOD) and limit of quantification (LOQ) were also investigated in the present study.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DN - Vliv životního prostředí na zdraví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Metallomics Technology Conference 2015. Recent Advances and Strategies: Conference Proceedings
ISBN
978-80-7509-309-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
32-35
Název nakladatele
Mendelova univerzita v Brně
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
14. 6. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—