Automatic electrochemical determination of soil contaminated by heavy metal ions (Cd(II) and Pb(II))
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F15%3A43907002" target="_blank" >RIV/62156489:43210/15:43907002 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62156489:43410/15:43907002
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Automatic electrochemical determination of soil contaminated by heavy metal ions (Cd(II) and Pb(II))
Popis výsledku v původním jazyce
Heavy metal pollution has become one of the most serious environmental problems of today. In this paper, we present low-cost and rapid production of amalgam electrodes, which were used for determination of Cd(II) and Pb(II). Difference pulse voltammetrywas used with following settings: initial potential -1,1 V; end potential -0.2 V; step potential 0.005 V; modulation amplitude 0.025 V; modulation time 0.057 s and interval time 0.2 sec. Optimized parameters were implemented in a robotic analyser. Samples were measured in 24-well plates with a flat bottom. The electrochemical robotic device included three moto-rized units and a positioning system. First unit was rigidly connected to the vertical frame of the electrochemical robot; electrode holder was attached to it and enabled precise vertical (z) positioning of electrode holder (up and down). Microtiter plate was placed on horizon-tally (x/y) positioned board. The limit of detection (LOD) was calculated for the geometric surface of th
Název v anglickém jazyce
Automatic electrochemical determination of soil contaminated by heavy metal ions (Cd(II) and Pb(II))
Popis výsledku anglicky
Heavy metal pollution has become one of the most serious environmental problems of today. In this paper, we present low-cost and rapid production of amalgam electrodes, which were used for determination of Cd(II) and Pb(II). Difference pulse voltammetrywas used with following settings: initial potential -1,1 V; end potential -0.2 V; step potential 0.005 V; modulation amplitude 0.025 V; modulation time 0.057 s and interval time 0.2 sec. Optimized parameters were implemented in a robotic analyser. Samples were measured in 24-well plates with a flat bottom. The electrochemical robotic device included three moto-rized units and a positioning system. First unit was rigidly connected to the vertical frame of the electrochemical robot; electrode holder was attached to it and enabled precise vertical (z) positioning of electrode holder (up and down). Microtiter plate was placed on horizon-tally (x/y) positioned board. The limit of detection (LOD) was calculated for the geometric surface of th
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DK - Kontaminace a dekontaminace půdy včetně pesticidů
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Metallomics Technology Conference 2015. Recent Advances and Strategies: Conference Proceedings
ISBN
978-80-7509-309-7
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
59-62
Název nakladatele
Mendelova univerzita v Brně
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
14. 6. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—