Automatic electrochemical determination of soil contaminated by heavy metal ions (Cd(II) and Pb(II))
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F15%3A43906293" target="_blank" >RIV/62156489:43210/15:43906293 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62156489:43410/15:43906293 RIV/00216305:26620/15:PU126152
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Automatic electrochemical determination of soil contaminated by heavy metal ions (Cd(II) and Pb(II))
Popis výsledku v původním jazyce
Heavy metal pollution has become one of the most serious environmental problems today. In this paper, we present low-cost and rapid production of amalgam electrodes, which were used for determination of Cd(II) and Pb(II). Difference pulse voltammetry wasused with following settings: initial potential -1,1 V; end potential -0.2 V; step potential 0.005 V; modulation amplitude 0.025 V; modulation time 0.057 s and interval time 0.2 sec. Production and setting parameters were optimized step by step. Optimized parameters were implemented in a robotic analyser. Samples were measured in 24-well plates with a flat bottom. The electrochemical robotic device included three motorized units and a positioning system. First unit was rigidly connected to the verticalframe of the electrochemical robot; electrode holder was attached to it and enabled precise vertical (z) positioning of electrode holder (up and down). Microtiter plate was placed on horizontally (x/y) positioned board. The limit of dete
Název v anglickém jazyce
Automatic electrochemical determination of soil contaminated by heavy metal ions (Cd(II) and Pb(II))
Popis výsledku anglicky
Heavy metal pollution has become one of the most serious environmental problems today. In this paper, we present low-cost and rapid production of amalgam electrodes, which were used for determination of Cd(II) and Pb(II). Difference pulse voltammetry wasused with following settings: initial potential -1,1 V; end potential -0.2 V; step potential 0.005 V; modulation amplitude 0.025 V; modulation time 0.057 s and interval time 0.2 sec. Production and setting parameters were optimized step by step. Optimized parameters were implemented in a robotic analyser. Samples were measured in 24-well plates with a flat bottom. The electrochemical robotic device included three motorized units and a positioning system. First unit was rigidly connected to the verticalframe of the electrochemical robot; electrode holder was attached to it and enabled precise vertical (z) positioning of electrode holder (up and down). Microtiter plate was placed on horizontally (x/y) positioned board. The limit of dete
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
DF - Pedologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
SGEM2015. Soils: Conference Proceedings
ISBN
978-619-7105-37-7
ISSN
1314-2704
e-ISSN
—
Počet stran výsledku
8
Strana od-do
65-72
Název nakladatele
STEF92 Technology Ltd.
Místo vydání
Sofia
Místo konání akce
Albena
Datum konání akce
18. 6. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000371663900009