Formation of G-quadruplex and Its Utilizing for an Automated Spectrometric Detection of Cisplatin
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F15%3A43907681" target="_blank" >RIV/62156489:43210/15:43907681 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26620/15:PU118485
Výsledek na webu
<a href="http://www.electrochemsci.org/papers/vol10/100503973.pdf" target="_blank" >http://www.electrochemsci.org/papers/vol10/100503973.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Formation of G-quadruplex and Its Utilizing for an Automated Spectrometric Detection of Cisplatin
Popis výsledku v původním jazyce
Here, we studied the formation of G-quadruplex using spectrophotometric methods (peroxidase activity of G-quadruplex) and verifications of obtained results by voltammetry (cytosine-adenine (CA) or guanine (G) peaks height). The results showed that the peroxidase activity of G-quadruplex increases with the increasing concentrations of K+ ions (1-20 mM) and Na+ ions (1-5 mM) with the highest values observed in the presence of K+ ions. The reverse trend was obtained with NH4+ ions, where the highest peroxidase activity was observed at the lowest concentration of NH4+ ions. The G-quadruplex formation was also proven electrochemically. The addition of 5 mM of K+ ions to the oligonucleotide solution with hemin caused a decrease of both determined peaks. Theperoxidase activity of G-quadruplex increased with the increasing concentration of Ag+ ions within the range from 40 nM to 5 mu M. Further, the addition of different concentration of cisplatin (0.5-2 mu M) to the G-quadruplex was monitore
Název v anglickém jazyce
Formation of G-quadruplex and Its Utilizing for an Automated Spectrometric Detection of Cisplatin
Popis výsledku anglicky
Here, we studied the formation of G-quadruplex using spectrophotometric methods (peroxidase activity of G-quadruplex) and verifications of obtained results by voltammetry (cytosine-adenine (CA) or guanine (G) peaks height). The results showed that the peroxidase activity of G-quadruplex increases with the increasing concentrations of K+ ions (1-20 mM) and Na+ ions (1-5 mM) with the highest values observed in the presence of K+ ions. The reverse trend was obtained with NH4+ ions, where the highest peroxidase activity was observed at the lowest concentration of NH4+ ions. The G-quadruplex formation was also proven electrochemically. The addition of 5 mM of K+ ions to the oligonucleotide solution with hemin caused a decrease of both determined peaks. Theperoxidase activity of G-quadruplex increased with the increasing concentration of Ag+ ions within the range from 40 nM to 5 mu M. Further, the addition of different concentration of cisplatin (0.5-2 mu M) to the G-quadruplex was monitore
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP102%2F11%2F1068" target="_blank" >GAP102/11/1068: Nano-elektro-bio-nástroje pro biochemické a molekulárně-biologické studie eukaryotických buněk (NanoBioTECell)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Electrochemical Science
ISSN
1452-3981
e-ISSN
—
Svazek periodika
10
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
CS - Srbsko a Černá Hora
Počet stran výsledku
15
Strana od-do
3973-3987
Kód UT WoS článku
000354782200024
EID výsledku v databázi Scopus
—