Thickness of the substantia compacta of porcine long bones
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16170%2F13%3A43872180" target="_blank" >RIV/62157124:16170/13:43872180 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Thickness of the substantia compacta of porcine long bones
Popis výsledku v původním jazyce
Mechanical load on the bone influences bone tissue and its inner tension, subsequently affecting bone formation and its histological structure. A precise understanding of this load and the development of strategies to influence it would contribute to principles of fracture management and to solving other bone pathologies of both humans and animals. The long bones of the thoracic and pelvic limb of a pig were here used as possible models to test new devices and implant materials. The purpose of this study was to investigate the thickness of compact bone of the diaphysis of porcine long bones and to establish ideal insertion points for tensometer probes, where 2.3 mm is the minimal required thickness, and to evaluate the histological structure of the compact porcine bone. A total number of 96 long bones from 12 pigs was investigated. The investigations consisted of morphometric assessment of the diaphysis of the bones by measuring thickness of the compact bone in different segments of th
Název v anglickém jazyce
Thickness of the substantia compacta of porcine long bones
Popis výsledku anglicky
Mechanical load on the bone influences bone tissue and its inner tension, subsequently affecting bone formation and its histological structure. A precise understanding of this load and the development of strategies to influence it would contribute to principles of fracture management and to solving other bone pathologies of both humans and animals. The long bones of the thoracic and pelvic limb of a pig were here used as possible models to test new devices and implant materials. The purpose of this study was to investigate the thickness of compact bone of the diaphysis of porcine long bones and to establish ideal insertion points for tensometer probes, where 2.3 mm is the minimal required thickness, and to evaluate the histological structure of the compact porcine bone. A total number of 96 long bones from 12 pigs was investigated. The investigations consisted of morphometric assessment of the diaphysis of the bones by measuring thickness of the compact bone in different segments of th
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
EA - Morfologické obory a cytologie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Veterinární medicína
ISSN
0375-8427
e-ISSN
—
Svazek periodika
58
Číslo periodika v rámci svazku
10
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
10
Strana od-do
543-552
Kód UT WoS článku
000328369900005
EID výsledku v databázi Scopus
—