Determination of trace elements in small volume of tissue
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16270%2F00%3A00000363" target="_blank" >RIV/62157124:16270/00:00000363 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of trace elements in small volume of tissue
Popis výsledku v původním jazyce
The article describes a method for determination of trace elements in small volume of tissue obtained from small animals or by biopsy. Weight of the native sample ranged between 10 mg and 100 mg with respect to possibility, determined analyte and ki nd of tissue. After solubilization the sample in 7.2 M HNO3 and dilution by organic solvent Cd, Cu and Pb were determined by graphite furnace atomic absorption spectrometry and Zn by flame atomic absorption spectrometry. The proposed procedure was validatedwith certified reference material of bovine liver (1577a SRM), bovine muscle (BCR CRM 184) and mussel (BCR CRM 278 ) and all results were in good agreement with the certified values (at 95% confidence level). The method provides a limit of detection (3s0) of 5, 38, 40 pg and 13 ng/ml for Cd, Cu, Pb and Zn respectively
Název v anglickém jazyce
Determination of trace elements in small volume of tissue
Popis výsledku anglicky
The article describes a method for determination of trace elements in small volume of tissue obtained from small animals or by biopsy. Weight of the native sample ranged between 10 mg and 100 mg with respect to possibility, determined analyte and ki nd of tissue. After solubilization the sample in 7.2 M HNO3 and dilution by organic solvent Cd, Cu and Pb were determined by graphite furnace atomic absorption spectrometry and Zn by flame atomic absorption spectrometry. The proposed procedure was validatedwith certified reference material of bovine liver (1577a SRM), bovine muscle (BCR CRM 184) and mussel (BCR CRM 278 ) and all results were in good agreement with the certified values (at 95% confidence level). The method provides a limit of detection (3s0) of 5, 38, 40 pg and 13 ng/ml for Cd, Cu, Pb and Zn respectively
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2000
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Development and Applications of Spectroscopic Methods. Proceedings of "4th European Furnace Symposium and XVth Slovak Spectroscopic Conference"
ISSN
80-88922-28-3
e-ISSN
—
Svazek periodika
3
Číslo periodika v rámci svazku
15
Stát vydavatele periodika
XX - osoby bez státní příslušnosti
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—