Popis výsledku v původním jazyce
The literature survey shows that the concentration of platinum group metals in diverse environmental matrices has increased significantly over the last two decades. Therefore, the amount of Pt and Pd released into the environment, their impact on human health, and routes for bioaccumulation and transformation in urban environment have to be monitored. Despite recent advances in instrumental techniques the analysis of Pt and Pd in geological, industrial, biological and environmental samples is still difficult task. Recently, we suggested a biosensor for determination of cadmium and zinc. Due to convincing results obtained, we focused on utilizing of the suggested biosensor to determine palladium. The suggested biosensor is consisted from hanging mercurydrop electrode and metallothionein (MT), which belongs to group of intracellular, cysteine-rich proteins with high affinity to heavy metals. To suggest biosensor, we utilized adsorptive transfer stripping technique (AdTS) coupled with di
Název v anglickém jazyce
A suggesting of biosensor for determination palladium
Popis výsledku anglicky
The literature survey shows that the concentration of platinum group metals in diverse environmental matrices has increased significantly over the last two decades. Therefore, the amount of Pt and Pd released into the environment, their impact on human health, and routes for bioaccumulation and transformation in urban environment have to be monitored. Despite recent advances in instrumental techniques the analysis of Pt and Pd in geological, industrial, biological and environmental samples is still difficult task. Recently, we suggested a biosensor for determination of cadmium and zinc. Due to convincing results obtained, we focused on utilizing of the suggested biosensor to determine palladium. The suggested biosensor is consisted from hanging mercurydrop electrode and metallothionein (MT), which belongs to group of intracellular, cysteine-rich proteins with high affinity to heavy metals. To suggest biosensor, we utilized adsorptive transfer stripping technique (AdTS) coupled with di
Klasifikace
Druh
M - Uspořádání konference
CEP obor
CG - Elektrochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Místo konání akce
Brno
Stát konání akce
CZ - Česká republika
Datum zahájení akce
—
Datum ukončení akce
—
Celkový počet účastníků
260
Počet zahraničních účastníků
170
Typ akce podle státní přísl. účastníků
WRD - Celosvětová akce