LC-MS analyses of microcystins in fish tissues overestimate toxin levels-critical comparison with LS-MS/MS
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16270%2F10%3A00002752" target="_blank" >RIV/62157124:16270/10:00002752 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
LC-MS analyses of microcystins in fish tissues overestimate toxin levels-critical comparison with LS-MS/MS
Popis výsledku v původním jazyce
Microcystins are cyclic peptide toxins with hepatotoxic and tumour-promoting properties which are produced in high quantities in freshwater cyanobacterial water blooms, and several studies have reported microcystin accumulation in fish with possible foodtransfer to humans. In this study, we provide the first comparison of liquid chromatography with single mass-spectrometric and with tandem massspectrometric detection for analyses of microcystins in complex fish tissue samples. Use of traditional singlemass spectrometry (i.e. monitoring of ions with m/z 519.5 for microcystin-RR and m/z 995.5 for microcystin-LR) was found to provide false-positive responses, thus overestimating the concentrations of microcystins in the tissue samples.More selective tandem mass spectrometry seems to provide more reliable results. The concentrations of microcystins detected by tandem mass spectrometry in fish from controlled exposure experiments were more than 50% Loir in comparison with concentrations o
Název v anglickém jazyce
LC-MS analyses of microcystins in fish tissues overestimate toxin levels-critical comparison with LS-MS/MS
Popis výsledku anglicky
Microcystins are cyclic peptide toxins with hepatotoxic and tumour-promoting properties which are produced in high quantities in freshwater cyanobacterial water blooms, and several studies have reported microcystin accumulation in fish with possible foodtransfer to humans. In this study, we provide the first comparison of liquid chromatography with single mass-spectrometric and with tandem massspectrometric detection for analyses of microcystins in complex fish tissue samples. Use of traditional singlemass spectrometry (i.e. monitoring of ions with m/z 519.5 for microcystin-RR and m/z 995.5 for microcystin-LR) was found to provide false-positive responses, thus overestimating the concentrations of microcystins in the tissue samples.More selective tandem mass spectrometry seems to provide more reliable results. The concentrations of microcystins detected by tandem mass spectrometry in fish from controlled exposure experiments were more than 50% Loir in comparison with concentrations o
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical and Bioanalytical Chemistry
ISSN
1618-2642
e-ISSN
—
Svazek periodika
398
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
7
Strana od-do
—
Kód UT WoS článku
000281670400008
EID výsledku v databázi Scopus
—