The rapid determination of bromadiolone in liver and blood plasma by in-injector pyrolysis gas chromatography-Ion trap tandem mass spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62157124%3A16270%2F17%3A43875945" target="_blank" >RIV/62157124:16270/17:43875945 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.jchromb.2017.10.027" target="_blank" >http://dx.doi.org/10.1016/j.jchromb.2017.10.027</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jchromb.2017.10.027" target="_blank" >10.1016/j.jchromb.2017.10.027</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The rapid determination of bromadiolone in liver and blood plasma by in-injector pyrolysis gas chromatography-Ion trap tandem mass spectrometry
Popis výsledku v původním jazyce
The unintentional poisoning of off-target animals by bromadiolone, a second generation anticoagulant rodenticide, is an undesirable outcome requiring sensitive analytical methods. In this study, a rapid and sensitive method for the determination of bromadiolone in liver and blood plasma by means of gas chromatography coupled with tandem mass spectrometry without need for derivatization was developed. The method is based on the in-injector pyrolysis of bromadiolone and subsequent gas chromatography coupled with ion trap tandem mass spectrometry with electron ionization. Sample preparation includes extraction with methanol, evaporation under nitrogen stream, and dissolution in toluene. The pyrolysis of bromadiolone was carried out in an injector at 390 °C. Chromatographic separation of the pyrolytical fragment of bromadiolone was achieved using a VF?5 ms column with helium as the mobile phase. Tandem in-time mass spectrometry of the separated pyrolytical fragment of bromadiolone was carried out using an ion trap mass spectrometer after electron ionization. Recovery ranged from 94 to 98%. The method showed good linearity up to 1000 ?g kg?1 for liver and 1000 ?g L?1 for plasma. The limit of detection was 0.38 ?g kg?1 for liver and 0.26 ?g L?1 for plasma. The developed method was used successfully in several animal poisoning cases.
Název v anglickém jazyce
The rapid determination of bromadiolone in liver and blood plasma by in-injector pyrolysis gas chromatography-Ion trap tandem mass spectrometry
Popis výsledku anglicky
The unintentional poisoning of off-target animals by bromadiolone, a second generation anticoagulant rodenticide, is an undesirable outcome requiring sensitive analytical methods. In this study, a rapid and sensitive method for the determination of bromadiolone in liver and blood plasma by means of gas chromatography coupled with tandem mass spectrometry without need for derivatization was developed. The method is based on the in-injector pyrolysis of bromadiolone and subsequent gas chromatography coupled with ion trap tandem mass spectrometry with electron ionization. Sample preparation includes extraction with methanol, evaporation under nitrogen stream, and dissolution in toluene. The pyrolysis of bromadiolone was carried out in an injector at 390 °C. Chromatographic separation of the pyrolytical fragment of bromadiolone was achieved using a VF?5 ms column with helium as the mobile phase. Tandem in-time mass spectrometry of the separated pyrolytical fragment of bromadiolone was carried out using an ion trap mass spectrometer after electron ionization. Recovery ranged from 94 to 98%. The method showed good linearity up to 1000 ?g kg?1 for liver and 1000 ?g L?1 for plasma. The limit of detection was 0.38 ?g kg?1 for liver and 0.26 ?g L?1 for plasma. The developed method was used successfully in several animal poisoning cases.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
40301 - Veterinary science
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Chromatography B
ISSN
1570-0232
e-ISSN
—
Svazek periodika
1070
Číslo periodika v rámci svazku
DEC 2017
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
4
Strana od-do
117-120