Stanovení dávky v panoramatické zubní skiagrafii
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F63108089%3A_____%2F05%3A00000008" target="_blank" >RIV/63108089:_____/05:00000008 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Dose assessment in panoramatic dental radiology
Popis výsledku v původním jazyce
Because of a similarity with CT examinations, a dose descriptor product of kerma and length PKL is used in panoramic radiology as well. The product of kerma and length in panoramic radiography is an integral of kerma profile created by the narrow beam ata front side of secondary collimator along a line perpendicular to the collimator. The quantity is integrated over the whole exposure cycle. There are three methods used for the PKL measurement, measurement can be performed by an X-ray film, by column of TLDs or pencil ionization chamber placed perpendicular to the secondary collimator. The results obtained through the mentioned methods agree within 10 % generally. A method of PKL measurement has been introduced in the Czech Republic to assess the doses received by patient, since no dose descriptor has been evaluated during QC test yet. A national diagnostic reference level will be assessed after collection and evaluation of a sufficient amount of data.
Název v anglickém jazyce
Dose assessment in panoramatic dental radiology
Popis výsledku anglicky
Because of a similarity with CT examinations, a dose descriptor product of kerma and length PKL is used in panoramic radiology as well. The product of kerma and length in panoramic radiography is an integral of kerma profile created by the narrow beam ata front side of secondary collimator along a line perpendicular to the collimator. The quantity is integrated over the whole exposure cycle. There are three methods used for the PKL measurement, measurement can be performed by an X-ray film, by column of TLDs or pencil ionization chamber placed perpendicular to the secondary collimator. The results obtained through the mentioned methods agree within 10 % generally. A method of PKL measurement has been introduced in the Czech Republic to assess the doses received by patient, since no dose descriptor has been evaluated during QC test yet. A national diagnostic reference level will be assessed after collection and evaluation of a sufficient amount of data.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/JB4%2F03" target="_blank" >JB4/03: Stanovení radiační zátěže pacientů při vyšetřeních v rentgenové diagnostice</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XXVII. Days of Radiation Protection : Conference Proceedings
ISBN
80-88806-53-4
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
160-161
Název nakladatele
—
Místo vydání
Liptovský Ján
Místo konání akce
Liptovský Ján
Datum konání akce
1. 1. 2005
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—